Effect of Irradiation on Vitamin C, Acidity and Moisture Content of Mango Fruits with Gamma Ray from Cobalt-60 Source
Idodo Maxwell, Ali Haruna, Adamu Baba-Kutigi, Eli Danladi
Asian Journal of Physical and Chemical Sciences · pp. 1–8 · Published 25 May 2017
10.9734/AJOPACS/2017/32297Abstract
In this study four varieties of mango fruits were irradiated with Gamma ray from Cobalt-60 source at different dose points of 50 Gy, 100 Gy, 300 Gy and 800 Gy in order to investigate the effect of irradiation on vitamin C, titreable acidity and moisture content. Studies indicate that the dose point of 0.05 KGy (sample A) and 0.10 KGy (sample B) gained an average vitamin C content of 6.88% and 6.27% respectively while the dose point of 0.30 KGy showed no loss or gained of vitamin C content and the dose point of 0.80 KGy (sample D) loss 56.25% of vitamin C as compared to reference point (un-irradiated or control sample). The values of titreable acidity which was high on day 2 decreases at day 10 and later increases at day 17. This is attributed to an increase in pulp acidity which occurred as the ripening process proceeds. Also a study reveals that irradiation has no effect on moisture content of mango fruit but can delay the rate of respiration thus the ripening and shelf life.
Cited by 2
A. Gabarty, A. Hammad, A.K.H. Amira Negm · Entomological news · 2025
Poulami Sarkar, Dipshikha Tamili, Paramita Bhattacharjee · Journal of food processing and preservation · 2021
Related research
- Analysis of Acceptance of Radiation Doses for Radiation Workers in the Radiology Facility of Bali Mandara Hospital — shares topic coverage
- Impact of Body Mass Index and Sex on Image Quality and Radiation Dose of Routine CT Scan — shares topic coverage
- Optimizing the Dose-Quality Paradigm in Low-Dose CT Lung Cancer Screening: A Narrative Review — shares topic coverage
- Chest CT Dose Examination for Adult Patient in Abuja and Keffi, Hospitals in Nigerian — shares topic coverage
- Abdominal CT Dose Examination for Adult Patient in Abuja and Keffi, Hospitals in Nigerian — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
2
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.