Impact of Body Mass Index and Sex on Image Quality and Radiation Dose of Routine CT Scan
Sulayman M.K., Aliyu S. A, I. Kamal, M.A.M Ariffin, Bashiru L., M. K. A Karim
Asian Journal of Medicine and Health · pp. 108–119 · Published 31 May 2025
10.9734/ajmah/2025/v23i61247Abstract
The purpose of this study is to investigate the relationship between radiation dose, signal-to-noise ratio (SNR), and image quality in routine CT scan. Emphasis is placed on the influence of anatomical regions and patient BMI on the metrics of image quality. A retrospective analysis was carried out on 136 patients (66 males and 70 females) who underwent routine CT examinations of the brain, thorax, and abdomen using a 16-slice CT scanner manufactured by GE Healthcare, USA. The Patients were categorized according to body mass index (BMI) as underweight (UW), normal weight (NW), overweight (OW), and obese classifications (OB). The image quality was assessed by measuring the signal intensity, noise (i.e. standard deviation S.D), and computing the signal-to-noise ratio (SNR) across the CT brain, CT thorax and CT abdomen. Statistical analysis, such as student’s t-tests, were conducted to evaluate differences in image quality metrics between both genders and BMI groups, with a significant p- value of < 0.05. The study recorded no significant differences in signal intensity, noise levels, and SNR between patients from both genders across the three anatomical regions (p > 0.05), suggesting that the imaging protocols ensured uniform image quality irrespective of gender. Nonetheless, as BMI increased, signal intensity and noise levels exhibited a significant increase (p < 0.05). Significantly, the SNR increased with increased BMI, indicating that larger patients had adequate radiation doses to improve image quality. Notwithstanding the increase in noise associated with increased BMI, the protocol effectively optimized the SNR to guarantee diagnostic image quality. Radiation dose tailoring according to anatomical region and BMI is important for image quality enhancement in CT scans, while reducing radiation exposure. These findings support the adoption of patient-specific dose optimization procedures in clinical practice to enhance diagnostic results.
Cited by 1
Z. Hamd, M. Abuzaid, M. Alharbi · Tomography · 2026
Related research
- Analysis of Acceptance of Radiation Doses for Radiation Workers in the Radiology Facility of Bali Mandara Hospital — shares topic coverage
- Optimizing the Dose-Quality Paradigm in Low-Dose CT Lung Cancer Screening: A Narrative Review — shares topic coverage
- Effect of Slice Thickness Variation on Spatial Resolution of CT-Scan Device Images at the Bali Mandara Hospital Radiology Installation — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
1
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.