Skip to content
Research Article Open access CC BY 3.0

Investigation of an Increase in Frequency of Scattered X-rays from a Silicon Single Crystal

Biswajit Mallick

Physical Science International Journal · pp. 198–216 · Published 9 Oct 2013

Abstract

Aims: X-ray scattered from a silicon single crystal was investigated.  A new scattered line with increased frequency was observed.   Study Design:  In order to ascertain that the new modified X-ray line observed is not accidental, an inelastic scattering experiment has been performed, using a grazing incidence X-ray instrument with a resolution of  2´10-3. Place and Duration of Study: Institute of Physics, Bubaneswar, India, between Jan 2011 and Nov 2011.  Methodology: In this experiment, X-rays are reflected from both the specimen and the focusing monochromator; which is known as reflection-reflection mode in double-crystal spectrometry (+1 -1).  Incident radiation from an X-ray tube operated at 40 kV and 40 mA was used to obtain polychromatic CuK X-ray photons in the order of photon/s to observe a new scattering pattern from Compton effect caused excited plasmon (life time 10 -16 s) standing wave in the silicon crystal. Results: CuK X-rays scattered from silicon (333) crystal of 15 × 15 mm2 and 1mm thick, possess unambiguous existence of a new modified line with increased frequency. The new scattering possesses high momentum transfer > kc, as high as = 6.16 ± 0.01 Å-1 and ( / kF)2 = 8.9. These findings are in agreement with the previous plasmon scattering results reported by various authors. The total cross section of this scattering is experimentally found out to be 2.95 ± 0.009 ´ 10-22 cm2/ electron and is inversely proportional to the third power of . Both theoretically calculated and experimentally observed wavelength shift data match well with each other. Conclusion: The new incoherent line was observed with the following major features:  the energy of the new modified peak is greater than that of the Rayleigh peak; the new modified peak observed is narrower than the Compton peak for the same incident X-rays line.  

X-ray scattering compton effect plasmon excitation radiation interaction

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.