Abdominal CT Dose Examination for Adult Patient in Abuja and Keffi, Hospitals in Nigerian
U. Rilwan, G. C. Onuchukwu, L.K. Sabiu, H. A. Abdullahi, I. Umar
Asian Journal of Advanced Research and Reports · pp. 36–44 · Published 24 Jan 2020
10.9734/ajarr/2020/v8i130191Abstract
This study has established local diagnostic reference levels (LDRLs). Dose report and scan parameters for abdomen was assessed during the period of seven months at the three study centres. Data on CT Dose index (CTDIw) and dose length product (DLP) available and achieved on CT scanner control console was recorded for a minimum of 10 average sized patients for each facility to established a local Diagnostic reference level (LDRLs) and radiation dose optimization Data was collected using a purposive sampling technique, from 131 adult patients weighing 70±3 kg) from Philip brilliance, Toshiba Alexion and General Electric (GE) CT scanners for this study. Third quartile values of the estimated LDRLs for CTDIw and DLP was determined as 12.7 mGy and 560 mGy*cm. The mean CTDIw obtained are lower to the reported data from the European Commission of 35 mGy. The mean DLP are comparably lower than all the reported value from the European commission of 780 mGy/cm. Therefore, there is no any clinical implication and hence CT dose optimization is recommended.
Cited by 0
No indexed citations yet.
Related research
- Analysis of Acceptance of Radiation Doses for Radiation Workers in the Radiology Facility of Bali Mandara Hospital — shares topic coverage
- Impact of Body Mass Index and Sex on Image Quality and Radiation Dose of Routine CT Scan — shares topic coverage
- Optimizing the Dose-Quality Paradigm in Low-Dose CT Lung Cancer Screening: A Narrative Review — shares topic coverage
- Chest CT Dose Examination for Adult Patient in Abuja and Keffi, Hospitals in Nigerian — shares topic coverage
- Head CT Dose Examination for Adult Patient in Abuja and Keffi, Hospitals in Nigerian — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.