Skip to content
Research Article Open access CC BY 4.0

Investigation of Groundwater Contamination from Septic Tank Siting in Umungasi/Abayi, Abia State

K. O. Nkem, C. L. Eze, I. U. Ini

Asian Journal of Biotechnology and Bioresource Technology · pp. 41–48 · Published 1 Feb 2021

10.9734/ajb2t/2020/v6i430088

Abstract

The investigation of groundwater contamination from septic tank siting was done in Umungasi/Abayi, Abia State. The aim of this study was to investigate the effect of siting septic systems on the quality of groundwater in Umungasi, Abayi, Aba. Twenty (20) water samples were randomly collected from boreholes located less than 30 m away from septic systems in Umungasi, Abayi Aba, Nigeria to determine their physico-chemical and heavy metals characteristics. While three (3) water samples at distances ranging from 60 m from the nearest septic system were sampled for analyses as controls. Standard analytical techniques were employed in the investigation. The result showed that most of the physicochemical parameters analysed in the borehole water samples were within the WHO/SON/NAFDAC recommended limits except for pH in BH4 and BH7 which had values of 6.3 respectively and were not within the WHO/SON/NAFDAC standard limit of 6.5-8.5. Some of the heavy metals analysed during the period of study were within the permissible limits except for iron in BH5 (0.443 mg/L), BH7 (0.367 mg/L), BH8 (0.511 mg/L), BH9 (0.31 mg/L), BH15 (0.41 mg/L), BH16 (0.327 mg/L), BH17 (0.337 mg/L) and BH18 (0.315 mg/L) that were above the permissible limits of WHO standards of 0.3 mg/l. There was no influence of septic tank siting to the boreholes on groundwater quality during the period of study even though the distance of septic tanks from boreholes in the areas investigated did not conform with that recommended by WHO of 30 – 40 m. The contamination is from the general unhygienic condition of the environment.

Boreholes groundwater quality heavy metals physicochemical characteristics septic tank.

References (1)

  1. 1 Investigation of Possible Groundwater Contamination from Septic System Siting in Port Harcourt, Nigeria

Cited by 1

Microbial quality of piped drinking water in Indonesia: Findings from the 2020 national household water quality survey

Rina Marina, I. Dharmayanti, Tities Puspita · Water supply : the review journal of the International Water Supply Association · 2026

Article metrics

Real usage data collected on this platform.

12

Page views

0

PDF downloads

1

Outbound clicks

1

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.