Integrated System for Accurate Electrical Measurement Monitoring
Taufik Muchtar, Atikah Tri Budi Utami, Lutfi, Hamdan Gani
Journal of Engineering Research and Reports · pp. 51–59 · Published 23 Jan 2024
10.9734/jerr/2024/v26i21071Abstract
Aims: This study aims to develop an integrated system for accurate electrical measurement monitoring. Study Design: The acquisition embedded system is developed using research and development study. Place and Duration of Study: Department of Machinery Automation System, Polytechnic ATI. Makassar, Indonesia, between March 2021 and October 2021. Methodology: The performance of the proposed integrated acquisition embedded system and conventional measurement is compared through different testing. Results: The results showed that the device worked as expected and was right on target. The device test error is compared with direct measurement with the measuring instrument; the voltage error is 0.17%, the current error is 0.46%, the power error is 0.89%, and the frequency error is 0.01%. System devices can measure and monitor several electricity measurements. Conclusion: The experimental results show that the system can function correctly. The integrated acquisition system can operate with great accuracy. This study is expected to contribute to establishing a system that will benefit the government's efforts to preserve energy efficiency.
Cited by 0
No indexed citations yet.
Related research
- Design of Intelligent Environment Monitoring System Based on CAN Bus — shares topic coverage
- Mobile Device and Software for Automating Body Measurements in Sheep — shares topic coverage
- Smart Trash Collection System – An IoT and Microcontroller-Based Scheme — shares topic coverage
- Innovation of a Low-Cost Water Quality Monitoring System in Aquaculture Ponds — shares topic coverage
- Design and Implementation of Intelligent Temperature-Regulating Fan System Based on STC89C52 — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.