Skip to content
Research Article Open access CC BY 4.0

Detection and Assay of Vitamin B6 (Pyridoxine Hydrochloride) Utilizing Isocratic High Performance Liquid Chromatography

Ronald Bartzatt, Purnima Gajmer, Mai Han Cassandra Nguyen, Alexandra My-Hanh Tran

Journal of Scientific Research and Reports · pp. 1–12 · Published 21 Oct 2016

10.9734/JSRR/2016/28991

Abstract

Aims: To demonstrate an analysis for vitamin B6 from commercial aqueous nutritional drinks and solid tablets, utilizing isocratic conditions with high performance liquid chromatography (HPLC) and UV detection at 290 nm. Study Design: Vitamin B6 in the form of pyridoxine hydrochloride is assayed by HPLC from various samples. Place and Duration of Study: Department of Chemistry, Durham Science Center, University of Nebraska, Omaha Nebraska from May to August 2016. Methodology: Utilizing a reversed-phase C-18 column with eluent solvent (19% ethanol, 77% water, 4% acetic acid), the samples were prepared in sample solvent (19% ethanol, 81% distilled water). Detection of vitamin B6 was accomplished at 290 nm. Analysis of samples was done following solubilizing in aqueous conditions having ethanol at 10% to 20% (v/v). Column pressure at 1900 psig, rise time 0.1 with flow rate 1.0 mL/minute. Elution peak for vitamin B6 occurred consistently at 1.6 minutes. Nutritional samples, aqueous samples, and solid pills were prepared in aqueous solvent with various levels of ethanol. Results: Levels of vitamin B6 detected were as low as 4.4029x10-5 molar to 7.8081x10-4 molar.  Sensitivity for vitamin B6 was highest at 290 nm.  Reverse phase isocratic conditions is shown to be effective for determination of vitamin B6 in aqueous based samples. Standard curves applied are highly linear in range from zero to 7.8081x10-4 molar (y = 112,521,145.5x + 2,818.6), having coefficient of determination (R2 = 0.9948) with very strong positive correlation coefficient (r= 0.9974). Percent recovery of vitamin ranged from 95% to 105%.  Amounts of vitamin present in drinks from same manufacturer were consistent. Conclusion: Utilizing reversed phase column, isocratic solvent conditions with ethanol in water, and a UV detector set at 290 nm is effective for determination of vitamin B6.  Ethanol-water solvent system is effective. Vitamin B6 was found in various amounts in nutritional drinks tested.

Pyridoxine hydrochloride vitamin B6 vitamin HPLC isocratic

Cited by 2

Voltammetric Determination of Vitamin B6 Using a Modified Gold Electrode

M. A. Kovanova, A. S. Postnov, A. S. Vashurin · Russian Journal of Physical Chemistry A · 2024

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

2

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.