Monitoring and Evaluation of The Reliability of Distribution Network with Distributed Generation
Stella Nkiruka EMECHETA, Raymond Onyeka Nwajuonye, George Chibuzor OKONKWO
Journal of Engineering Research and Reports · pp. 29–42 · Published 30 Dec 2021
10.9734/jerr/2021/v21i1217510Abstract
With the growing population of Ezenei 11KV feeder radiating from the Asaba mains Injection Substation and overstretched distribution network, monitoring and evaluation of the reliability and improvement of distribution network feeder is essential. Failure of some of the equipment at supply restoration is frequent due to weakness of some of the line conductors and long usage of the equipment. In this research work, simulation, analysis and evaluation of the reliability and improvement of Ezenei 11kV feeder was investigated. Load data used were collected from Benin Electricity Distribution Company (BEDC) Asaba between February and April 2018 and this was used to model the sixty – seven (67) buses on the network using Electrical Transient and Analysis Program (ETAP). Load flow analysis was carried out on the modelled network using Newton – Raphson (N-R) iteration method to determine the various bus power (active and reactive) and voltage magnitude using the base and distributed generation injected power. Reliability study was carried out on the network and result showed that the load point indices were increasing as distance of load point increased from feeder. The Seventeen load buses which was Okeke bus to Starcom bus forms the location A. and St. Rebecca bus to Chief Ofili bus forms location B. while Odogu bus to Old Deputy Govt. bus forms location, Iyabi bus to MTN III bus forms location D. Okeke and Jimok water which are the closest load buses to the feeder have an Average Interruption Rate (f/yr) and Annual Output Interruption Rate (hr/yr) of 8.9264f/yr, 417.1507hr/yr while Victor Odogu and Auditor General has an Average Interruption Rate (f/yr) and Annual Output Interruption Rate (hr/yr) of 8.9318f/yr, 417.2857hr/yr and 8.9264 f/yr, 417.1507hr/yr. It was also observed that Chief Osita, Anacho and Estate buses had the highest Average Interruption Rate (f/yr) and Annual Output Interruption Rate (hr/yr).
Cited by 1
D. Boyarkov, B. Kompaneets · Power engineering (Barrington, Ill.) · 2024
Related research
- Anxiety and Visual Field Assessment Reliability in Glaucoma Patients — shares topic coverage
- Home Recording And Video Selection: Their use In A Low-Resource Setting For Epilepsy Diagnosis — shares topic coverage
- A study on Clinical Validity and Reliability of the Bengali Language Translated Gastroesophageal Reflux Disease Quality of Life Questionnaire (GERD-QOL) in Gastroesophageal Reflux Disease Patients — shares topic coverage
- Reliability of the General Nutrition Knowledge Questionnaire among Head Teachers from Schools in Uganda — shares topic coverage
- Validity and Reliability of Combination of Observed Practice with Objective Structured Clinical Examination (OSCE) in Midwifery Final Exam — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
1
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.