Suitability of Lower K2 EDTA Sample Volumes for Absolute CD4 Count Enumeration by Flow Cytometric Technique
K. A. Fasakin, O. D. Ajayi, C. T. Omisakin, A. J. Esan
International Blood Research & Reviews · pp. 117–123 · Published 16 Apr 2015
10.9734/IBRR/2015/16338Abstract
Background: Incorrect blood sample volume-anticoagulant ratio has been the cause of both haematological and immunological errors especially when K3 EDTA-containing blood collection tubes were used. Lower whole blood sample volumes collected into 4.0 millilitres spray-dried K2 EDTA has been shown to overcome incorrect haematology results when analysed on automated haematology analyzers but there is no experimental evidence for the same in the CD4 count enumeration by flow cytometric technique. Materials and Methods: 9.0 ml of whole blood was collected from each of fifteen retroviral and ten normal volunteers and aliquot into five different 4.0 ml plastic spray-driedK2 EDTA blood collection tubes containing 4.0, 2.0, 1.5, 1.0 and 0.5 ml respectively. Each well-mixed sample was analysed on Partec Cyflow counter within 4 hours of collection for absolute CD4+T lymphocyte count. Results: Both the reference sample volume 4.0 ml and experimental lower sample volumes (2.0, 1.5, 1.0 and 0.5 mls) of retroviral volunteers in 4.0 ml plastic spray-driedK2 EDTA blood collection tubes gave comparable CD4 count results with percentage mean difference of 1.82%, -1.48%, 2.25% and 0% for 2.0 ml, 1.5 ml 1.0 ml and 0.5 ml respectively. Irrespective of sample volumes, the normal volunteers had higher CD4 count results. There was no statistically and clinically significant difference in the CD4 counts and the percentage mean difference were 0.4%, 0.17%, 1.00% and 0.23% for 2.0 ml, 1.5 ml, 1.0 ml and 0.5 ml respectively. The correlation (slope)and modest logistic regression coefficient (R2) of experimental lower sample volumes of both retroviral and normal volunteers were between 0.9500 and 1.0000 showing excellent agreement in the CD4 counts of both reference and experimental sample volumes(p<0.01). Conclusion: Quality CD4 count results can be obtained with a minimum sample volume of 0.5 ml in 4.0 ml spray-dried K2 EDTA vacutainer blood collection tubes both in HIV and healthy individuals with intact immune function. Funding: This research did not receive any grant from any funding agency in the public, commercial or non-profit sector.
Cited by 0
No indexed citations yet.
Related research
- Normal CD4 Count in Healthy Voluntary Blood Donors in the Jigme Dorji Wangchuck National Referral Hospital, Thimphu, Bhutan — shares topic coverage
- Assessment of CD4 Count and Some Haematological Parameters of HIV Positive Patients Co-infected with Hepatitis B Virus in Osun State, Nigeria — shares topic coverage
- Effect of HIV Infection and Antiretroviral Therapy Duration on CD4 Count, Total and Differential White Cell Count — shares topic coverage
- Fungal Isolation in HIV Patients and CD4 Count — shares topic coverage
- Susceptibility Pattern of Different Parts of Moringa oleifera against Some Pathogenic Fungi, Isolated from Sputum Samples of HIV Positive Individuals Co-Infected with Pulmonary Tuberculosis — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.