Skip to content
Research Article Open access CC BY 4.0

Enhancement of a Decentralized Wastewater Treatment System by Applying a Bio-tower - A Project for Improving our Environmental Footprint

Klaus Dölle

Journal of Engineering Research and Reports · pp. 24–41 · Published 19 Jun 2023

10.9734/jerr/2023/v25i4900

Abstract

To investigate if decentralized wastewater treatment systems impact on the environment performance can be improved, a Field Bio-tower Tank Septic system was designed, installed on an existing 1,500-gal (5678 l) decentralized wastewater treatment system. The system was started up during a 14-day start-up phase, followed by a 130-day test phase. The system was operated at an average hydraulic retention time of 16.7 days based on a 90 gal (204.4 l) daily influent wastewater flow. The systems recirculation flow for the bio-tower was 22.6 l/min (6 gal/min) for the start-up phase and 40.0 l/min (10.6 gal/min) for the test period with a corresponding recirculation of the entire septic tank from 5.7 to 10.1 times a day respectively. During the testing period a daily average temperature of 19.3°C (66.7°F) and an average rainfall of 5 l/m² was observed. The FBST system operated at an average influent pH level and temperature of 8.6 and 22.0°C. The average effluent pH and temperature was 8.5 of 20.9°C. The installed system reduced on average the influent TS from 79151 mg/l to 43021 mg/l and showed an average reduction of the TDS from 36424 mg/l to 21965 mf/l. The TSS and VSS was reduced on average from 94.1 mg/l to 69.9 mg/l and 89.0 mg/l to 64.9 mg/l. NH3-N content was reduced from 57.5 mg/l in the influent to 53.4 mg/l in the effluent. The average BOD and COD was reduced from the average influent value of 88.2 mg/l and 318.2 mg/l to 66.8 mg/l and 256.2 mg/l respectively. However, at the end of the 130-day test period BOD and COD values were the lowest at 15.5 mg/l and 56.0 mg/l respectively, indicating bacteria cultures are well established and the system operation of the FBTS system is mostly constant. This research showed that the FBST system can improve operations of a DWWTS system significantly reducing the effluent load over 10 times compared to the influent load of the system.

Bio-tower decentralized wastewater treatment contaminants effluent septic system sewage wastewater wastewater treatment

References (12)

  1. 1 Biological Wastewater Treatment in Warm Climate Regions
  2. 2 Pharmaceuticals in On‐Site Sewage Effluent and Ground Water, Western Montana [DOI]
  3. 3 Concentrations of hormones, pharmaceuticals and other micropollutants in groundwater affected by septic systems in New England and New York [DOI]
  4. 4 Biogeochemical Evolution of Domestic Waste Water in Septic Systems: 1. Conceptual Model [DOI]
  5. 5 Oxygen Demand, Chemical [DOI]
  6. 6 Algae to Remove Phosphorous in a Trickling Filter [DOI]
  7. 7 Application of Subsurface Bioreactor for Wastewater Treatment [DOI]
  8. 8 Bio-tower Application for Wastewater Treatment [DOI]
  9. 9 Municipal Wastewater Treatment Using a Packed Bio-tower Approach [DOI]
  10. 10 Bio-Tower Application for Improvement of a Decentralized Waste Water Treatment System for Residential Applications–Reduction of Nonpoint Source Pollution by Nitrogen [DOI]
  11. 11 Benchtop Septic System for Effluent Treatment - A Laboratory Development [DOI]
  12. 12 Journal of Engineering Research and Reports [DOI]

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

27

Page views

0

PDF downloads

7

Outbound clicks

0

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.