Skip to content
Research Article Open access CC BY 4.0

Contact Analysis for Coupling of Plates and Screws in Fracture Fixation of Cortical Bone

Gaffar Gailani, Rachid Moumni, Malek Brahimi

Advances in Research · pp. 94–101 · Published 9 Jan 2015

10.9734/AIR/2015/14189

Abstract

Internal fixation is a common treatment for bone fracture. Bone fracture occurs due to different reasons such as motor vehicle accidents, falling,…etc. The treatment is performed by fixing plate and screws to the fracture site. Lack of stability of the implants (plates and screws) may lead to delay in healing or failure of treatment. Micro-motion between the implant and the bone may cause formation of fibrous tissue around the screw which will lead to implant loosening. On the other hands, firm fixing of the conventional implants (Dynamic Compression Plates) may lead to delay resorption and delay in healing. Recently, Locked Compression Plates were introduced to get over the shortcomings of the existing Dynamic Plates. In Locked Plates the hole and screw head were threaded to provide more stability and reduce contact with the bone surface. In this communication we conducted computational analysis to compare the stability of both sets of implants. Results have revealed that Locked Plates provide more stable fixation and resistance to micro-motion. However, stress shielding might occur which will delay healing. Future designs of the Locked Plates can focus on improving stability and reducing damage to blood supply which will shorten the healing period. Computational analysis (finite element analysis) can be effectively used to guide these future designs.   

Internal fixation of bones locked plates in bones dynamic compression plate 3-D FEA model for bone fracture

References (10)

  1. 1 EVOLUTION OF THE INTERNAL FIXATION OF LONG BONE FRACTURES [DOI]
  2. 2 Biomechanics of bone-fracture fixation by stiffness-graded plates in comparison with stainless-steel plates [DOI]
  3. 3 Finite Element Analysis of Osteosynthesis Screw Fixation in the Bone Stock: An Appropriate Method for Automatic Screw Modelling [DOI]
  4. 4 Stress protection due to plates: myth or reality? A parametric analysis made using the composite beam theory [DOI]
  5. 5 The influence of screw omission on construction stiffness and bone surface strain in the application of bone plates to cadaveric bone [DOI]
  6. 6 Principles of external fixation of the femur.
  7. 7 Evaluation of one-, two-, and three-dimensional finite element and experimental models of internal fixation plates [DOI]
  8. 8 EXTERNAL FIXATION FOR OPEN FRACTURES OF THE UPPER EXTREMITY [DOI]
  9. 9 Effect of screw position on bone tissue differentiation within a fixed femoral fracture [DOI]
  10. 10 [The treatment of tibia open fractures by Hoffmann external fixation in Niamey. About 50 cases].

Cited by 1

Article metrics

Real usage data collected on this platform.

2

Page views

0

PDF downloads

0

Outbound clicks

1

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.