Quality Control Assessment of Diagnostic X-Ray Units in Zanzibar, Tanzania
Suleiman Ameir Suleiman, Salum Kombo Salum, Ebenezer Kimaro
Physical Science International Journal · pp. 1–9 · Published 31 Dec 2020
10.9734/psij/2020/v24i1230228Abstract
Regular execution of quality control (QC) tests in medical diagnostic X-ray units is primarily important to provide high-quality images and proper diagnoses with least hazard. The performance criteria in diagnostic radiology in Zanzibar Islands, Tanzania were followed in accordance with the QC guidelines, and the values of the measured parameters were compared with the tolerance limits. The study was designed to perform QC tests on the diagnostic X-ray units in governmental and private hospitals. In this study six QC tests (beam alignment, beam collimation, kV reproducibility, half-value layer (HVL), mAs linearity and kV accuracy) were carried out by using beam alignment tool and Unfors non-invasive X-ray test device (Xi R/F&MAM detector). The measured parameters were conducted in two periods, from 2017 to 2018 (14 X-ray units were considered) and from 2019 to 2020 (16 X-ray units were considered). In both periods, the QC test results indicated that 100% of the X-ray units had acceptable HVL≥ 2.3 mm Al at 80 kVp. In the first period (2017−2018), the QC results showed that 78.57% and 85.71% had acceptable beam alignment (≤3% of the focus to image distance) and beam collimation (≤ ± 2 cm). Of the X-ray units evaluated, 85.71% had tolerable kV reproducibility of 5%, and 71.43% had mAs linearity within the tolerance limit of 10%, whereas 85.71% had acceptable kV accuracy within the tolerance limit of 5%. In the second period (2019−2020), the tolerance limits of X-ray units exceeded by 8.04% for kV reproducibility, 8.04% for kV accuracy, 16.07% for mAs linearity, 8.93% for beam alignment and 8.04% for beam collimation. The exceeded tolerance limits could be attributed to the new X-ray units which have full support of service agreements signed during the second period and increase of the compliances with the Tanzania Atomic Energy Act. No 7 of 2003 and its regulations. Results obtained highlight the need to regularly carry out comprehensive QC tests together with routine equipment maintenance.
Cited by 1
1 citation reported by external sources — individual citing-article records aren't available to list yet.
Related research
- Effect of Slice Thickness Variation on Spatial Resolution of CT-Scan Device Images at the Bali Mandara Hospital Radiology Installation — shares topic coverage
- Impact of Body Mass Index and Sex on Image Quality and Radiation Dose of Routine CT Scan — shares topic coverage
- Optimizing the Dose-Quality Paradigm in Low-Dose CT Lung Cancer Screening: A Narrative Review — shares topic coverage
- Effect of Contrast and Brightness on Digital Images under Outdoor Conditions — shares topic coverage
- Image Content Enhancement of Natural Images Using Genetic Algorithm — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
1
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.