Skip to content
Research Article Open access CC BY 4.0

Benchtop Septic System for Effluent Treatment - A Laboratory Development

Klaus Dölle, Simon Lex

Journal of Engineering Research and Reports · pp. 34–40 · Published 1 Jul 2022

10.9734/jerr/2022/v22i1017571

Abstract

One in every five households in the United States of America operates a decentralized water treatment systems which is also know as septic system, which may contribute to pollutions in water bodies if not operated properly. For this research a 15.0-liter (3.97 gal.) laboratory benchtop septic system was designed, build, installed and operated at a temperature of 23.0°C (73.4°F) to investigate the remediation of municipal wastewater. A three-week start-up phase was used prior to operating the system with unfiltered wastewater collected from primary clarifier at a wastewater treatment. The operational test phase included an hydraulic retention rate of 5, 10 and 20 days which corresponds to 3000 ml/d, 1500 ml/d, and 750 ml/d respectively. Based on the above results, the laboratory benchtop septic system minimum effluent values for the chemical oxygen demand are 18±1 mg/l, and 60±10 mg/l for the total solids content, and <5±1 mg/l for the total suspended solids. These values correspond to the published effluent concentration range of 30% to 80% of influent concentrations for septic tanks. The results show, that the laboratory benchtop septic systems is able to reduce the chemical oxygen demand, total solids content, and total suspended solids content level of municipal wastewater and can be a valuable tool to access the performance of septic systems utilizing different wastewater influent types.

Contaminants decentralized water treatment system remediation septic system sewage wastewater

References (9)

  1. 1 UNITED STATES ENVIRONMENTAL PROTECTION AGENCY [DOI]
  2. 2 Small and decentralized wastewater management systems
  3. 3 Pharmaceuticals in On‐Site Sewage Effluent and Ground Water, Western Montana [DOI]
  4. 4 Concentrations of hormones, pharmaceuticals and other micropollutants in groundwater affected by septic systems in New England and New York [DOI]
  5. 5 Biogeochemical Evolution of Domestic Waste Water in Septic Systems: 1. Conceptual Model [DOI]
  6. 6 Algae to Remove Phosphorous in a Trickling Filter [DOI]
  7. 7 Application of Subsurface Bioreactor for Wastewater Treatment [DOI]
  8. 8 Municipal Wastewater Treatment Using a Packed Bio-tower Approach [DOI]
  9. 9 Bio-Tower Application for Improvement of a Decentralized Waste Water Treatment System for Residential Applications–Reduction of Nonpoint Source Pollution by Nitrogen [DOI]

Cited by 5

Study of Treating Wastewater with a Laboratory Benchtop Septic Systems

Klaus Dölle, Malina Fritz · Journal of Engineering Research and Reports · 2022

Performance of indigenous bacterial consortia for bioremediation of domestic wastewater

S. Sukmawati, A. Birawida, Ambeng Ambeng · Ecological Engineering & Environmental Technology · 2026

Showing 4 of 5 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

30

Page views

0

PDF downloads

7

Outbound clicks

5

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.