New Possibilities of Refractive Modeling of the Cornea by the Radiation of an Argon-fluorine Excimer Laser
Ophthalmology Research: An International Journal · pp. 7–18 · Published 25 Nov 2021
10.9734/or/2021/v15i330213Abstract
Purpose: To consider new possibilities of refractive modeling of the cornea by the radiation of an argon-fluorine excimer laser in ablative and subablative modes after saturation of the stroma with riboflavin. Materials and Methods: Experimental (20 pork, 90 rabbit eyes) and clinical studies on photorefractive and phototherapeutic operations with saturation of the corneal stroma with riboflavin (610 operations) were analyzed. To activate riboflavin, secondary radiation induced by exposure to ablative and subablative energy densities was used. A quick transition to energy densities below the ablation threshold without additional calibrations was carried out using a “Microscan Visum-500” excimer laser (Optosystems, Russia). An objective assessment of the refractive keratomodelling effect and visual results was carried out according to the data of complex optometric studies. Results: Experimental and clinical studies have shown the advantages of refractive keratomodeling by theradiation of an argon-fluorine excimer laser in ablative and subablative modes after saturation of the stroma with riboflavin. Isotonic 0.25% riboflavin solution did not affect the accuracy of refractive ablation and blocked the negative effect of induced secondary radiation on keratocytes and corneal nerves. This reduced the aseptic inflammatory response and the risk of developing an irreversible form of fibroplasia. Ablation with riboflavin initiated a damped crosslinking effect, which increased the photoprotective and strength properties of the thinned cornea. A refractive keratomodelling effect was found when energy densities were applied below the stromal ablation threshold. The magnitude of this refractive effect depended on the total radiation dose and the topography of the affected area. This approach made it possible to implement laser-induced refractive keratomodeling without ablation of the corneal stroma. Conclusion: Refractive modeling of the cornea by the radiation of an argon-fluorine excimer laser in ablative and subablative modes after saturation of the stroma with riboflavin opens up new possibilities in laser correction of ametropia.
Cited by 0
No indexed citations yet.
Related research
- Detection and Assay of Riboflavin (Vitamin B2) Utilizing UV/VIS Spectrophotometer and Citric Acid Buffer — shares topic coverage
- Repair of Severe Melting Ulcers with High Intensity UV-pen (18 to 60 mW/cm2) Corneal Cross-linking (CXL) and Amniotic Membrane Graft — shares topic coverage
- Efficacy S-formula and Kinetics of Non-oxygen-mediated (Type-I) and Oxygen-mediated (Type-II) Corneal Cross-linking — shares topic coverage
- Photochemical Kinetic Modeling for Oxygen-enhanced UV-light-activated Corneal Collagen Crosslinking — shares topic coverage
- Kinetics of Enhancement for Corneal Cross-linking: Proposed Model for a Two-initiator System — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.