Skip to content
Research Article Open access CC BY 4.0

Development and Validation of New Analytical Method for Determination of Particle Size Distribution in Alogliptin Benzoate Drug Substance Using Laser-based Particle Size Analyzer

Jitendra Kumar Dubey, Jitendra Koundinya, Babul Nishad, Praveen Choubay, Nirav Parekh, Mehul Gujrati, Pankaj T. Shah, Frenil Vaidya

Journal of Advances in Medical and Pharmaceutical Sciences · pp. 29–38 · Published 18 Aug 2026

10.9734/jamps/2026/v28i9887

Abstract

Particle size distribution (PSD) characterisation is important for pharmaceutical drug-substance quality because particle size can influence formulation-related performance. This study developed and validated a wet-dispersion laser-diffraction method for determining the PSD of Alogliptin Benzoate using the Malvern Mastersizer 3000 (Ultra Plus). Methanol, chloroform, and liquid paraffin light were evaluated during method development, and liquid paraffin light was selected as the dispersion medium. The optimised measurement conditions included a particle refractive index of 1.50, dispersant refractive index of 1.468, sample absorption value of 1.0, obscuration of 10–20%, stirrer speed of 2000 rpm, and sonication for 45 seconds. Method performance was assessed using Dᵥ10, Dᵥ50, and Dᵥ90 through precision, intermediate precision, and robustness studies. Method precision produced %RSD values of 3.00%, 2.47%, and 3.91% for D(0.1), D(0.5), and D(0.9), respectively. Intermediate precision gave corresponding %RSD values of 3.46%, 3.40%, and 8.77%. The cumulative %RSD values for method and intermediate precision were 3.21%, 3.30%, and 6.80%, respectively. Robustness was evaluated by deliberate changes in stirrer speed, obscuration range, and sonication time, with the reported results remaining within the stated acceptance criteria. The developed procedure therefore demonstrated consistent performance under the conditions evaluated and is suitable for routine particle size determination of Alogliptin Benzoate drug substance in quality control laboratories.

Alogliptin benzoate drug substance particle size distribution wet dispersion Malvern Mastersizer 3000 method validation robustness

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.