An Assessment of Causative Factors of Building Collapse using Physical Analysis Tests: The Case of Oko, Anambra State, Nigeria

C. O. Obiora, I. S. Ezennia, C. B. N. Bert-Okonkwo, O. E. Chukwuemerie

Journal of Engineering Research and Reports · pp. 1–11 · Published 5 Jan 2022

10.9734/jerr/2022/v22i117512

Abstract

Incessant building collapses in Anambra State Nigeria is posing serious challenges to all the stakeholders in the building industry - building consultants, governments, developers, landlords and users. This has evoked great concern to all key players of the building industry. Thus, this study assessed the causative factors of building collapses in one of the cases, a collapsed uncompleted 3-story building which was reported in Oko town, Anambra State, Nigeria. A qualitative methodology involving subsoil and geotechnical investigation and also destructive testing of collapsed structural elements including sandcrete blocks, concrete and reinforcement bars; to establish the subsoil conditions, compressive strength, the yield stress as well as ductility of the reinforcements bars was adopted for this study. The results of the test carried out on the mass concrete, revealed a compressive strength ranging from 1.4N/mm2 to 3.1N/mm2 (standard compressive strength of 25N/mm2), 6” solid block ranging from 0.3N/mm2 to 0.4N/mm2 and 6” hollow block ranging from 0.2N/mm2, (standard strength value of 1.5 N/mm2 for a non-load bearing sandcrete block in accordance to NIS: 587:2007). The tensile stress of the reinforcement bars (12mm and 16mm) ranging from 280.29N/mm2 to 303.91N/mm2 (According to NIS: 117:2004, standard yield stress value of 410N/mm2 and ductility of 12%). The CPT revealed that the subsoil is generally too soft and the fine aggregate (sand) was poor for concreting. The findings suggest that poor foundation structure, inappropriate mix of concrete, the use of substandard materials, inadequate reinforcement and poor project supervision, contributed to the structural failure that lead to the collapse of the building. Therefore, this research recommends that mandatory, periodic or conditional structural integrity assessment of buildings in use and under construction becomes an exclusive preserve of highly qualified construction professionals. Standard organization of Nigeria should be vigilant to ensure that building materials imported into the country conforms to standard requirements especially the reinforcement bars.

Building collapse sub-soil investigation destructive test compressive strength, tensile stress

Cited by 1

Defects in Concrete Elements: A Study of Residential Buildings of 30 Years and above in Onitsha Metropolis, Anambra State, Nigeria

Chiamaka Ogochukwu Obiora, Fidelis Okechukwu Ezeokoli, Christopher Chidi Belonwu · Journal of Building Construction and Planning Research · 2022

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

1

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.