Appraising of Air Conditional System Condensate Discharge Rate in Southwest, Nigeria

O. S. Bamisaye, P. K. Oke, U. A. Essien

Journal of Scientific Research and Reports · pp. 1–7 · Published 17 Jan 2019

10.9734/JSRR/2018/45470

Abstract

Aims: The aim of this research is to ascertain the condensate discharge rate from a split air conditional system with a view to channeling the condensate into a storage tank for other useful purposes. Study Design: Quantitative study. Relevant data on condensate discharge rate was collected. Place and Duration of Study: Department of Mechanical Engineering, The Federal University of Technology, Akure, Ondo State, Nigeria, between 16th to the 22nd of November, 2015. Methodology: The method used consists of data collection and readings such as outdoor dry bulb temperature, dew point temperatures, relative humidity, and condensate volume. It features the calculation of air conditioning load estimation, data analysis, and estimated cost of integrating condensate collection which is essential for the completion of this study. Results: The study discovered that about three thousand four hundred and eighty-eight (3,488) litres of condensate are being wasted on a weekly basis within the School of Engineering and Engineering Technology, The Federal University of Technology, Akure. This figure indicates the amount of reclaimed water source that is not in use. Conclusion: The condensate can/should be collected with the help of 2hp capacity pump and channeled through a pipe of diameter 32 mm into a 5000 litres capacity tank within the engineering building. The condensate can flow through the existing plumbing facilities and will serve to address a lot of water scarcities being experienced, most especially in many laboratories, toilets and by cleaners at School of Engineering and Engineering Technology Building. This will reduce the cost being spent per month on water supply by the faculty and would result to great annual savings.

Air condition cooling load estimation reclaim water modern building

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.