Skip to content
Research Article Open access CC BY 4.0

UV Spectrophotometric Methods to Quantify Alogliptin Benzoate and Pioglitazone Hydrochloride

Dhanya B. Sen, Ashim K. Sen, Aarti S. Zanwar, Harshita Pandey, Rajesh A. Maheshwari

Journal of Pharmaceutical Research International · pp. 31–41 · Published 17 Jul 2021

10.9734/jpri/2021/v33i37B32017

Abstract

Three new, precise, accurate and sensitive UV-Spectrophotometric methods namely Ratio Difference Spectroscopic Method (RDSM), First Derivative of Ratio Spectra Method (DR1) and Area Under Curve Method (AUC) were developed and validated for simultaneous assessment of alogliptin benzoate (ALO) and pioglitazone hydrochloride (PIO) in tablet dosage form. In RDSM, ratio spectra of both the drugs were recorded by dividing the mixtures using interfering drug as divisor. Then the difference between the amplitudes of obtained ratio spectra was measured at 288 and 291 nm for ALO and 236 and 245 nm for PIO. The second method DR1, where the first derivative of ratio spectra of both the drugs were recorded and the first derivative signal was measured at 290 nm for ALO and 276.8 nm for PIO. The scaling factor was fixed as 1 and wavelength interval (Δλ) as 2 for recording the first derivative of ratio spectra.  In the third method (AUC), peak area of recorded zero order spectra was measured at 276 ± 10 nm for ALO and 267.8 ± 10 nm for PIO. All three proposed methods were validated according to “International Conference on Harmonization” (ICH) guidelines parameters. For all three methods, ALO and PIO obeyed Beer’s law in the range of 0.5-5 & 1.8-18 µg/ml, respectively. The % RSD of repeatability of measurement, intra-day and inter-day precision were found to be less than 2 for all three methods. Limit of detection (LOD) and Limit of quantification (LOQ) of the drugs were calculated which proved the sensitivity of the methods. The accuracy ranged between 98-101% for all three methods. No interference from pharmaceutical excipients present in the formulation was observed.  These proposed methods were found to be simple, sensitive, accurate and precise and can be applied to the simultaneous estimation of ALO and PIO in combined tablet formulation and also appropriate for routine quality control analysis.

Alogliptin benzoate pioglitazone hydrochloride ratio difference spectroscopic method first derivative of ratio spectra method area under curve method laboratory prepared tablet formulation

Cited by 7

Densitometric simultaneous assessment of teneligliptin hydrobromide and pioglitazone hydrochloride in combined tablet

Ashim Kumar Sen, Neel Bhimani, Dhanya B. Sen · SEPARATION SCIENCE PLUS · 2023

Gliptin combinations: A Review on analytical methods

Mukthinuthalapati Mathrusri Annapurna, Sathya Sree Guduru · Journal of Drug Delivery and Therapeutics · 2024

Different Innovative UV-spectroscopic Approaches for Simultaneous Assessment of Celecoxib and Tramadol Hydrochloride in Binary Mixture

Ashim Kumar Sen, Preksha Darji, Dhanya B. Sen · Indian Journal of Pharmaceutical Education and Research · 2023

Thiazolidinediones: Recent Development in Analytical Methodologies

Tarang Patel, Vatsal Patel · Journal of Chromatographic Science · 2023

Novel UV Spectrophotometric approaches for the concurrent determination of Teneligliptin and Metformin in Tablet Formulation

Dhanya B. Sen, Ashim Kumar Sen, Aarti S. Zanwar · Research Journal of Pharmacy and Technology · 2024

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

7

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.