Skip to content
Research Article Open access CC BY 4.0

Use of Single Mini-plate Versus Two Miniplates Osteosynthesis for Linear Non-comminuted Fracture of Anterior Mandible: A Prospective Randomized Comparative Study

Muhammed Ajnas T, Abhinandan Patel, Girish Gowda, Preethi Bhat, AKSHIT BATRA

Journal of Advances in Medicine and Medical Research · pp. 146–155 · Published 7 Feb 2025

10.9734/jammr/2025/v37i25728

Abstract

Mandibular fractures are the most common fractures within the facial skeleton. The management of mandibular fractures has evolved from closed techniques such as maxillomandibular fixation (MMF), splints, and external stabilization to rigid internal fixation. This study aims to evaluate and compare the stability and recovery times in anterior mandibular fractures after open reduction with either single or dual miniplate fixation. All patients with anterior mandibular fractures underwent preoperative computed tomography (CT) scans and post-operative radiographic evaluations following open reduction and internal fixation (ORIF). Group 1 included 10 patients who were treated with a 2.5mm single miniplate (comprising 6 holes with a gap), while Group 2, also consisting of 10 patients, received treatment with one 2mm miniplate and one 2.5 mm miniplate, being placed at the lower border (each having 4 holes with a gap). An arch bar was used in the mandibular arch for a duration of 3 weeks in both groups. Patients were assessed at one week, four weeks, and twelve weeks after the procedure as part of a follow-up protocol, focusing on factors such as postoperative occlusion, the stability of the fractured segments, bite force measured with a specific device, neurosensory deficits, wound dehiscence, and damage to the roots of the anterior and bicuspid mandibular teeth. Our study effectively showed that a single miniplate provided stability comparable to that of a two-miniplate system in managing anterior mandibular fractures after open reduction and internal fixation.

Mandibular fracture symphysis parasymphysis open reduction internal fixation miniplates

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

1

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.