Under-voltage Protection of Power Transmission Lines
Journal of Energy Research and Reviews · pp. 40–46 · Published 4 Aug 2023
10.9734/jenrr/2023/v15i1296Abstract
The continuous monitoring of the protection relay of the transmission line is desirable to ensure the system disturbance such as fault inception is detected in the transmission line. Therefore, the fault on the transmission line needs to be detected, classified, and located accurately to maintain the stability of the system. This paper presents design enhancement and development under voltage relay in power system protection using MATLAB/Simulink. The contacts of the under-voltage relay operate when voltage drops below a set voltage. It is used for protection against voltage drops to detect the short circuit. This work is carried out for all types of faults which only related to one of the parallel transmission lines. In overall operation conditions, the sample data were generated for the system by varying the different fault types and fault locations. This design system proposes the use of the MATLAB/Simulink-based method for fault classification and location of various types of faults.
References (13)
- 1 Orthogonal least squares learning algorithm for radial basis function networks [DOI]
- 2 A new fault location technique for two- and three-terminal lines [DOI]
- 3 Application of RBF neural network to fault classification and location in transmission lines [DOI]
- 4 Voltage stability enhancement in grid-connected microgrid using enhanced dynamic voltage restorer (EDVR) [DOI]
- 5 Implementation of protection circuit for over voltage and under voltage protection [DOI]
- 6 Transmission line fault location for single-phase-to-earth fault on non-direct-ground neutral system [DOI]
- 7 Relay-based undervoltage load shedding scheme for Entergy's Western Region [DOI]
- 8 Performance of an Over/Under Voltage Relay at Non-sinusoidal Conditions [DOI]
- 9 Design of a High Precision Undervoltage Protection Circuit Based on High Voltage BCD Technology [DOI]
- 10 Design of Under Voltage Relay for an Industrial Plant with Cogeneration Units to Enhance Power Quality of Critical Loads [DOI]
- 11 Fault location in power distribution systems considering a dynamic load model [DOI]
- 12 Under-voltage relay settings for the tie-lines tripping in an upgrading cogeneration plant [DOI]
- 13 Ingeniería e Investigación [DOI]
Cited by 3
Nico Ewaldo Fan Gulo, Pristisal Wibowo, Ahmad Dani · RIGGS: Journal of Artificial Intelligence and Digital Business · 2025
Showing 1 of 3 known citations — external sources report more than can currently be individually listed.
Related research
Article metrics
Real usage data collected on this platform.
13
Page views
0
PDF downloads
14
Outbound clicks
3
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.