HPLC, Densitometric and Visible-Spectrophotometric Determination of Triclabendazole and Ivermectin
Sawsan Razeq, Asmaa El-Demerdash, Hoda El-Sanabary
British Journal of Pharmaceutical Research · pp. 1–14 · Published 10 Jan 2016
10.9734/bjpr/2016/29196Abstract
Two methods were developed for simultaneous determination of triclabendazole and ivermectin, in addition to a Vis-spectrophotometric method for the analysis of ivermectin only. The first one was HPLC method in which efficient separation of two drugs was achieved on a C18 column with isocratic elution and a mobile phase composed of acetonitrile-methanol-0.005M KH2PO4 in a ratio of (60:30:10, v/v/v), pH 6. The linearity range was found to be 2.5-50 µg mL-1 for triclabendazole and 1-20 µg mL-1 for ivermectin with mean accuracy of 100.11% ± 0.99 and 100.08% ± 0.53, respectively. The second method was a densitometric evaluation of thin-layer chromatograms of the two drugs using a mobile phase of chloroform-acetone (8: 2, v/v). The plates were visualized under UV lamp at 254 nm where spots appeared at Rf 0.79 and 0.33 for triclabendazole and ivermectin, respectively. The chromatograms of the two drugs were measured densitometrically at 306 nm in the range 2.5-25.0 µg/spot for triclabendazole and at 245 nm in the range of 0.5-5.0 µg/spot for ivermectin with mean accuracy of 100.38% ± 0.52 and 100.05% ± 0.41, respectively. The Vis-spectrophotometric method was applied for the determination of ivermectin depending on its reducing character on tetrazolium red to give highly colored red product absorbing maximally at 485 nm in the range of 10-200 µg mL-1 with mean accuracy of 100.61% ± 0.43. The first two methods provided selective recovery of triclabendazole and ivermectin (100.53% ± 0.97 and 100.03% ± 0.82, 99.94% ± 1.60 and 98.77% ± 0.72; respectively). While the third Vis-spectrophotometric method provided selective recovery of ivermectin (100.86% ± 0.93) in presence of triclabendazole. Successful application of the methods for analyzing triclabendazole and ivermectin in their pharmaceutical formulations was obtained. The validity of the method was evaluated in terms of linear regression analysis, precision, accuracy and selectivity.
Cited by 7
Omkulthom Mohamed Al Kamaly, Lateefa A. Al‐Khateeb, Asmaa Othman El-Demerdash · Microchemical Journal · 2025
Hind A Abdullatif, Mohamed A. A. Abdelkawy, Shereen A. Boltia · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · 2024
Mahmoud M. Sebaiy · Medicinal & Analytical Chemistry International · 2021
AYAN KUMAR KAR, Banhishikha Kar, Beduin Mahanti · Asian Journal of Pharmaceutical and Clinical Research · 2020
· Medicinal & Analytical Chemistry International · 2018
Showing 5 of 7 known citations — external sources report more than can currently be individually listed.
Related research
- Reasons Why Students Study Medicine: Views of Students at Delta State University Abraka, South-South Nigeria — shares topic coverage
- Harnessing Artificial Intelligence in Healthcare Analytics: From Diagnosis to Treatment Optimization — shares topic coverage
- Exploring Hemophilic Pseudotumors: A Comprehensive Case Series — shares topic coverage
- A Novel Catalytic Synthesis of Flavones under Autoclave Conditions and Comparative Study of Anti-cancer Activity — shares topic coverage
- HPTLC Densitogram Profile of Aqueous Distillate (Arka) from Roots of Boerhaavia diffusa — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
7
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.