Skip to content
Research Article Open access CC BY 3.0

The Efficacy of QuikClot Combat Gauze, Fluid Resuscitation and Movement on Hemorrhage Control in a Porcine Model of Hypothermia

Brian Gegel, James Burgert, John Gasko, Sabine Johnson, Jennifer Florez, E. Edward Dunton II, Don Johnson

Journal of Advances in Medicine and Medical Research · pp. 1483–1493 · Published 13 Dec 2013

10.9734/BJMMR/2014/7262

Abstract

Aims: The purpose of this study was to compare the effectiveness QuikClot Combat Gauze (QCG) to a control group on hemorrhage control and investigate the effects of intravenous volume resuscitation on rebleeding and movement on hemostasis in a porcine model of hypothermia. Design: This was a prospective, between subjects, experimental design. Twenty-two Yorkshire swine were randomly assigned to two groups: QCG (n = 11) or control (n=11). Methods: The femoral artery and vein were transected. After 1 minute of uncontrolled hemorrhage, the hemostatic agent QCG was placed into the wound followed by standard wound packing. The control group underwent the same procedures without QCG. After 5 minutes of manual pressure, a pressure dressing was applied to the injury site. Initial resuscitation was performed with 500 mL of rapidly administered IV 6% Hetastarch. Following 30 minutes of observation, the dressings were removed and any additional blood loss was collected and total blood loss calculated. Hemostasis was defined as <2% total blood volume or ~ 100 mL in a 70 kg swine. If hemostasis occurred, 5 Liters of IV crystalloid were rapidly administered and the wound was again observed for rebleeding. If no bleeding occurred, the extremity on the side of the injury was systematically moved through flexion, extension, abduction and adduction sequentially 10 times or until rebleeding occurred. Results: There were significant differences in hemorrhage (P=.01), the amount of volume resuscitation (P =.01) and movement (P =.03) between the QCG and control groups. Conclusion: QCG is effective and statistically superior at controlling hemorrhage, allows for greater fluid resuscitation, and tolerates significant movement without rebleeding compared to the standard pressure dressing control in this hypothermic porcine model of uncontrolled hemorrhage.

Hypothermia hemorrhage control hemostatic agents Quikclot combat gauze.

Cited by 7

Analysis of tourniquet pressure over military winter clothing and a short review of combat casualty care in cold weather warfare

Raimund Lechner, Yannick Beres, Amelie Oberst · International Journal of Circumpolar Health · 2023

Hemostatics in patients with inhibited coagulation—A viscoelastic in‐vitro analysis

Raimund Lechner, Katharina Hanke, Anna Schmid · Transfusion · 2023

Progress and future prospects of hemostatic materials based on nanostructured clay minerals

Yinfeng Yang, Xiaomei Wang, Fangfang Yang · Biomaterials Science · 2023

The effects of QuikClot Combat Gauze on hemorrhage control in the presence of hemodilution and hypothermia

Don Johnson, Sheri Bates, Sofiya Nukalo · Annals of Medicine & Surgery · 2014

Showing 4 of 7 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

10

Page views

0

PDF downloads

8

Outbound clicks

7

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.