The Influence of Anti-scatter Grid Usage for Knee Computerized Radiography
Luísa Vargas Cassol, Nataly Nogueira Favarin, Felipe de Bail, Edmeia Lopes Ramai Buss, Laura Pizarro Trojahn Nogueira, Jéssica Fetzer da Costa Rosa, Thiago Victorino Claus
Physical Science International Journal · pp. 29–41 · Published 13 May 2024
10.9734/psij/2024/v28i4834Abstract
Aims: This experimental study investigated the effect of using an anti-scatter grid in computerized knee radiography (CR) on image quality (IQ) and patient surface radiation dose (Equivalent Surface Air Kerma – Ka,e), measured with an ionization chamber. Place and Duration of Study: The experimental study was conducted between February 2024 and April 2024, in the radiodiagnosis laboratory belonging to the Medical Physics and Radiology Technology courses at the Franciscan University (UFN) in the city of Santa Maria, Rio Grande do Sul. Methodology: Utilizing a semi-anatomical knee phantom to simulate clinical examination conditions, ten images were acquired, with five obtained using technique 1 (70 kV, 200mA, and 20mAs) and another five with technique 2 (70 kVp, 200mA, and 5 mAs), with and without an anti-scatter grid, respectively. The phantom images were digitized in a CR system and quantified using a publicly available automatic analyzer software based on histograms and regions of interest (ROI), defined by signal and noise. The obtained results were used to calculate the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and radiographic contrast (RC), considered IQ descriptors. Results: As a selection criterion, the percentage deviation (D%) was chosen, considering technique 1 as the reference concerning technique 2. It was observed that technique 1 showed an SNR 1.20%, RC 3.86%, and Ka,e 73.68% higher than technique 2; on the other hand, technique 2 indicated a CNR 4.76% higher compared to technique 1. Conclusion: It is concluded that technique 2 without an anti-scatter grid may be preferable when considering the principle of optimization, where the dose is significantly reduced without a significant loss in IQ descriptors.
Cited by 0
No indexed citations yet.
Related research
- Radiographic Anatomy of the Canine Appendicular Skeleton — shares topic coverage
- Radiographic Anatomy of the Abdomen of Local Breed Dogs — shares topic coverage
- Cardiotoxic Assessment of Radiographic Developer Effluent in Wistar Rats — shares topic coverage
- Comparison of the Radiopacity of Zinc Oxide-eugenol Cements using Different Radiographic Methods — shares topic coverage
- Clinical Evaluation, Diagnosis and Surgical Management of Traumatic Pharyngitis in a Non-descript Cattle — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.