Comparative Analysis of the Mollon-reffin Minimal Colour Vision Test in Visually ‘Normal’ and Acquired Ocular Disease
Hetan Ajwani, Carmel P. Noonan, Fiona J. Rowe
Ophthalmology Research: An International Journal · pp. 65–77 · Published 7 Dec 2013
10.9734/OR/2014/7274Abstract
Aim: Currently a variety of different colour vision tests exist in clinical practice each with its own merits and limitations. The Ishihara test is commonly used to test for congenital deficiency, causing red-green deficits. However acquired deficiency is also common in any ocular pathology affecting the optic nerve. The aim of this study is to compare the Mollon-reffin Minimal Test (MRMT) against the Ishihara and City colour vision tests. Methods: All three tests were performed within the same clinic visit with a small rest between tests. The main parameters of interest were correlation levels between tests for defect detection, severity grading and defect type classification. We assessed the time taken to complete testing and evaluated the patients experience of test. Results: We assessed 100 patients and 54 visually ‘normal’ subjects, with re-testing in the latter group to evaluate test-retest reliability. We found a reasonable level of agreement between the MRMT and the other tests once considering possible confounders for defect detection, severity grading and defect type classification in the patient group. There was a strong level of agreement in the visually normal group which suggests a high specificity relative to the other tests. The time taken to perform the MRMT is clinically acceptable in comparison to the City Test. Conclusions: Patients experiences of the MRMT were positive and they preferred it to the other tests. We recommend that the MRMT be used detect colour vision defects or monitor deficiency, in patients with a significant visual field defect.
Cited by 0
No indexed citations yet.
Related research
- Diagnostic Accuracy of Computed Tomography Abdomen with Surgical Findings for Blunt Abdominal Injury Cases — shares topic coverage
- Diagnostic Accuracy of Artificial Intelligence for Breast Cancer Detection: A Systematic Review — shares topic coverage
- Role of Serum C-Reactive Protein in Improving the Diagnostic Accuracy of the Modified Alvarado Score in Patients with Suspected Acute Appendicitis: A Cross-sectional Study — shares topic coverage
- Improving Diagnostic Accuracy in Clinical Chemistry: Evaluation of Pre-Analytical and Analytical Errors in Resource-Limited Laboratories of Developing and Underdeveloped Countries — shares topic coverage
- Explainable Artificial Intelligence, Clinician Trust and Diagnostic Accuracy in Multi-modal Medical Imaging: A Critical Narrative Review — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.