Abstract

A selective, simple and new reversed phase high performance liquid chromatographic method (HPLC) was developed and validated for simultaneous determination of tinidazole (TIN)  and  lidocaine (LID) in the ovule  dosage form in this study. Developed method was performed with gradient elution by getting C18 (250x4.6mm,5µm) reversed phase HPLC column, mobile phase containing 10mM potassium phosphate buffer (pH3.0), acetonitrile at 1.0 mL/min. Temperatures for  column  and autosampler were adjusted at 25Cº. The chromatographic separation was carried out at 220 nm  wavelength. Retention times were found as 6.5 min for LID and 8.2 min. for TIN. The purity of each substance was evaluated  getting a photodiode array detector. The  linearity ranges  were 75.0-195.0 µg/mL for TIN and 25.0-65.0 µg/mL for  LID. The  limit of dedection (LOD) and  the  limit of quantitation (LOQ)  results were  0.05625 µg/mL and 0.225 µg/mL for TIN,  0.01875 µg/mL and 0.075 µg/mL for LID, respectively.  The simple, sensitive and reproducible method was applied for simultaneous determination of TIN and LID in pharmaceutical preparations successfully.

HPLC lidocaine ovule pharmaceutical preparations tinidazole

Cited by 4

Analytical Approaches for the Determination of Lidocaine and Its Metabolites: A Comprehensive Insight

Hemn A. H. Barzani, Rebaz Anwar Omer, Nergz Bayiz Abdulrahman · Critical Reviews in Analytical Chemistry · 2026

Overview of Analytical Methods for Evaluating Tinidazole

Jean Carlos Pereira Sousa, Ana Carolina Kogawa · Journal of AOAC INTERNATIONAL · 2022

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

4

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.