Seismic Response of Stiffness Irregularity at Ground Floor with and without Shear Walls
Kirtika Kumawat, Trilok Gupta, R. S. Shekhawat, Yash Agrawal
Journal of Scientific Research and Reports · pp. 12–24 · Published 4 Jan 2024
10.9734/jsrr/2024/v30i11819Abstract
In today's scenario, one of the greatest challenges for structural engineers is designing and constructing seismic-resistant structures. Seismic activity, or earthquakes, poses a significant threat to civil engineering structures, and ensuring that buildings can withstand the forces generated during an earthquake is crucial for public safety and infrastructure resilience. Irregular configurations, whether in the building's floor plan or its elevation, are widely acknowledged as significant contributors to failure during seismic events. These irregularities can lead to uneven distribution of forces and stresses, compromising the building's ability to withstand the seismic forces and potentially resulting in structural failure. Soft storeys, typically located at ground levels for various functional purposes, pose challenges in seismic regions due to their lack of sufficient lateral load-resisting elements resulting in excessive lateral deformation and collapse during intensive earthquakes. Hence, the present study investigated the seismic response of irregular reinforced concrete structures possessing stiffness irregularity at ground floor with and without shear walls. A ten-storey regular frame is modified by incorporating vertical irregularity in elevation by increasing the height of the ground floor. The complete structural analysis and modeling are carried out by using the software ETABS 2020. The Time History method is applied, and the study is focused on seismic zones V in India. The performance of structures are compared based on criteria such as storey displacement, storey drift, storey shear and overturning moment. The results lead to the conclusion that a building structure exhibiting stiffness irregularity is prone to instability which is indicated by higher displacement and drift values. Structures incorporating shear walls have demonstrated greater stability compared to structures without shear wall as they exhibited higher base shear values and experienced a reduction in lateral displacement by more than 40%. The presence of shear walls also has enhanced the stability and strength of the structure, showing a linear response during critical earthquakes.
Cited by 0
No indexed citations yet.
Related research
- Status of Post-traumatic Stress Disorder (PTSD) and Its Associated Factors among Secondary School Students after Fifteen Months of Earthquake in Bhaktapur District, Nepal — shares topic coverage
- Simultaneous Measurement of Groundwater Radon in a Large Area: First Results — shares topic coverage
- Earthquake Effects on Slope Stability by Using Finite Element Method. Case Study: Brazzaville City, Republic of Congo — shares topic coverage
- Seismic Vulnerability Assessment in Tunnels: A Review — shares topic coverage
- The Use of Exponential Distribution Model to Estimate Recurrence Periods of Earthquakes in Zimbabwe — shares topic coverage
Article metrics
Real usage data collected on this platform.
12
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.