Scheimpflug Imaging of Late-onset Capsular Bag Distention Syndrome Treated with Nd: YAG Laser: A Case Report
Andreas Katsimpris, Maria Moleron, Aristotelis Karamaounas, Stylianos Kandarakis
International Journal of Medical and Pharmaceutical Case Reports · pp. 6–11 · Published 26 Jan 2023
10.9734/ijmpcr/2023/v16i1323Abstract
Aims: To report a case of very late-onset capsular bag distention syndrome (CBDS) 8 years after uncomplicated cataract surgery treated with Neodymium: Yag (Nd: Yag) laser posterior capsulotomy. Presentation of the Case: A 76-year-old female patient without any systemic or ocular disorders, presented with progressive blurry vision in her right eye (RE) over the last 1 year. Best-corrected visual acuity (BCVA) was 6/9 in the right eye and 6/6 in the left eye. Manifest refraction revealed a 0.5 diopters myopic shift in her RE compared to her last ocular examination 2 years ago. Scheimpflug photograpgy and slit-lamp examination were utilized to make the diagnosis of CBDS, which was successfully treated with Nd: Yag laser posterior capsulotomy. At day 1 post-capsulotomy the BCVA of her RE improved to 6/6 with a 0.5 diopters hyperopic shift which was consistent with a 0.13 mm post-capsulotomy increase in the anterior chamber depth, as documented by the Scheimpflug images. Discussion and Conclusion: Late-onset CBDS can manifest after a considerable time period following cataract surgery and Scheimpflug imaging can be a useful aid for a precise diagnosis and documentation of the treatment.
Cited by 0
No indexed citations yet.
Related research
- A Prospective Pilot Study Comparing the Retinal Layer Effects of Two Techniques for Nd: Yag Laser Posterior Capsulotomy — shares topic coverage
- Clinical and Risk Factor Profile of Infants Treated with Bevacizumab or Nd: YAG Laser for Retinopathy of Prematurity — shares topic coverage
- Efficacy of Treatment of Diabetic Macular Edema through Frequency-Doubled ND:YAG Laser (532NM) Green Laser — shares topic coverage
- Comparing Refractive and Scheimpflug-image Based Parameters between Right and Left Eyes and between Dominant and Non-dominant Eyes Related to Handedness — shares topic coverage
- Comparison of Ultrasound and Scheimpflug Methods for Central Corneal Thickness — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.