Numerical Study of a Thermal Plume Developing in a Neutral Environment and in Interaction: Application to Fires Problems
Zeinebou Yahya, Mulook Masoud Alharbi
Journal of Scientific Research and Reports · pp. 218–232 · Published 5 Mar 2024
10.9734/jsrr/2024/v30i41907Abstract
This study focuses on the mathematical and numerical modelling of how different properties, such as channel length and hot source height, affect the flow of thermal plumes and their interaction with the surrounding environment. Studying the behaviour of a directed thermal plume flow can provide a good visualisation of the control parameters for various applications related to fires and pollutants. To determine the control parameters affecting this flow, it is imperative to initially analyse the flow through a natural convection consisting of a disc-shaped heat source at the inlet of a vertical cylinder using mathematical and numerical methods. The flow in this study is characterised by natural convection, turbulent, steady, two-dimensional and incompressible. Numerical results were obtained via computational fluid dynamics analysis, which is based on mathematical flow modelling using the system of Navier–Stokes equations and the finite volume method. The SIMPLE algorithm was used for the velocity–pressure coupling. After introducing the concept of Reynolds averaging and analysis, different RANS turbulence models are presented, particularly two-equation models, using the Ansys Fluent software. Comparison of the different profiles revealed the ideal flow control parameters. An improvement in thermal properties was observed when the height of the heat source was hs = 1.5 cm and the vertical length of the channel was D = 20cm.
Cited by 0
No indexed citations yet.
Related research
- The Significance of Time Step Size in Simulating the Thermal Performance of Buildings — shares topic coverage
- Determination of Optimal Geometry for an Empty Concentrator Augmented Wind Turbine — shares topic coverage
- Computational Fluid Dynamics of Air in Forced Draft Counter Flow Wet Cooling Tower: Using Comsol Multi-Physics — shares topic coverage
- Validation of Enclosure Fire Model in Integral form Using an Inverse Approach — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.