Reversible Ventricular Dysfunction in Tachycardia-induced Cardiomyopathy: Implications for Timing of ICD Therapy

Bethel O. Anekwe, Adaku S. Ndubisi, Chimaobi Nwevo

Asian Journal of Research in Cardiovascular Diseases · pp. 347–356 · Published 1 Oct 2026

10.9734/ajrcd/2026/v8i1170

Abstract

Tachycardia-induced cardiomyopathy is a potentially reversible cause of left ventricular systolic dysfunction that can develop in the setting of persistent or frequently recurrent tachyarrhythmias. Recognition is clinically important because ventricular recovery after rhythm control may alter decisions regarding primary-prevention implantable cardioverter-defibrillator therapy. We report the case of a 58-year-old man with hypertension who presented with several weeks of progressive exertional dyspnoea, palpitations, reduced exercise tolerance, and mild volume overload. Electrocardiography demonstrated typical atrial flutter with 2:1 atrioventricular conduction and a ventricular rate of approximately 150 beats/min. Transthoracic echocardiography showed left ventricular dilation, global hypokinesis, a left ventricular ejection fraction of 29%, and a left ventricular end-diastolic diameter of 6.6 cm. Coronary angiography did not show obstructive coronary disease, and no alternative reversible cause of cardiomyopathy was identified. As tachycardia-induced cardiomyopathy was suspected, rhythm control was prioritised. The patient underwent cavotricuspid isthmus catheter ablation, with successful termination of atrial flutter and restoration of sinus rhythm. Guideline-directed medical therapy for heart failure was continued, and primary-prevention implantable cardioverter-defibrillator implantation was deferred pending reassessment. At 3-month follow-up, symptoms had improved substantially, and repeat echocardiography demonstrated recovery of systolic function, with left ventricular ejection fraction improving from 29% to 66% and left ventricular end-diastolic diameter decreasing from 6.6 cm to 4.7 cm. These clinical and imaging findings supported deferral of permanent device therapy at that time. This case highlights the importance of identifying potentially reversible arrhythmia-mediated ventricular dysfunction and reassessing cardiac function after durable rhythm control before committing selected patients to permanent device therapy.

Tachycardia-induced cardiomyopathy atrial flutter arrhythmia-mediated cardiomyopathy catheter ablation reverse remodelling left ventricular dysfunction implantable cardioverter-defibrillator rhythm control sudden cardiac death device-therapy timing

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

1

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.