Skip to content
Research Article Open access CC BY 4.0

Quantitative Assessment of Age and Gender Related Changes in Human Lacrimal Fluid Composition in Subjects

Ohwin Ejiro Peggy, Ofulue Ofioritse Ogheneyoma, Nwogueze Bartholomew Chukwuebuka, Agbonifo-Chiiokwu Ejime, Omeru Oghenerukevwe, Nwangwa Eze Kingsley

Journal of Pharmaceutical Research International · pp. 89–99 · Published 2 Jul 2021

10.9734/jpri/2021/v33i34B31851

Abstract

Purpose: The frequency of eyelids blink rate has effect on the integrity of the tear fluid and replacement of old of tears on the ocular surface. Comprehension of the effect of advancing age and gender on tears fluid stability and quality is contentious. Basal tears continuously bathe the ocular facet lubricating and providing protection from viral and bacterial infections, cooling the surface as warmth encourages pathogen. Basal tear dysfunction basically results in conjunctival and corneal conditions which exposes the ocular facet to dryness, ulceration, opacity and even blindness. This study determined the quantitative assessment of age and gender related changes in human lacrimal fluid composition in subjects Methods: The design involved 400 (192 males and 208 females) human subjects aged 6 years and above who do not wear contact lenses, not on topical medication and having healthy eyes grouped into twelve groups based on age and gender.  Maximum blink interval (for tear break-up time) and phenol red thread procedure (for tear volume) were carried out monocularly for each subject. Results: Findings from this study have established that tear fluid stability among different age groups; are often higher for group 6-12years and lower for 60years and above; therefore, study established that tear fluid stability is age dependent. In addition, tear fluid stability (average MBI. Tear volume and flow rate) are gender independent. Conclusion: The present study revealed that tears fluid breakup time increases with decrease in tears fluid flow rate, volume and flow.

Tears fluid tear flow tear volume Maximum blink interval

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

19

Page views

0

PDF downloads

14

Outbound clicks

0

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.