Power Loss Mitigation Using Distributed Generation in Asaba Distribution Network
Raymond Onyeka Nwajuonye, Chibuzor George Okonkwo, Innocent Ifeanyi Okonkwo
Journal of Engineering Research and Reports · pp. 161–181 · Published 2 Jun 2026
10.9734/jerr/2026/v28i61921Abstract
The increasing demand for electricity, coupled with rising economic and environmental concerns, has made renewable energy, particularly solar energy, a major area of interest. This research work evaluates the impact of distributed generation (DG) and presents a methodology for the optimal allocation and sizing of distributed generation within a distribution network in order to minimise power losses and improve voltage profiles. The study involved load flow analysis of the existing 15MVA, 33/11kV Benin Electricity Distribution Company (BEDC) Asaba injection substation distribution network and its 11kV radial feeders (SPC and Anwai Road), connected to an aggregate of ninety-six (96) 11/0.415kV secondary distribution transformers serving as load buses. Simulation, analysis, and integration of photovoltaic (PV) distributed generation into the Asaba injection substation distribution network were carried out using the Newton–Raphson algorithm and the Loss Sensitivity Factor (LSF) algorithm to determine the optimal location and size of the DG units. The network was modelled in ETAP version 12.6 using a detailed single-line diagram developed in the ETAP editing environment. The results revealed that, prior to DG installation, only ten (10) out of the ninety-six (96) buses operated within the statutory voltage limits of 394.25V–435.75V (0.95–1.05 p.u.), while eighty-six (86) buses violated the permissible voltage range. This indicated that the network was weak, unstable, and characterised by high active and reactive power losses of 1329.08kW and 2031.16kVAr, respectively. Following the optimal placement of DG units, active and reactive power losses were reduced by 57.5% and 70.7%, respectively. In addition, ninety-one (91) out of the ninety-six (96) buses operated within the statutory voltage limits. This improvement significantly enhanced the capacity, reliability, and operational efficiency of the distribution network.
Cited by 0
No indexed citations yet.
Related research
- Modeling and Comparative Analysis of PV Module with Improved Perturbation & Observation Based MPPT Technique for PV Applications — shares topic coverage
- A General Review on Photovoltaic, Modeling, Simulation and Economic Study to Build 100 MW Power Plant in Lebanon — shares topic coverage
- Photovoltaic Energy Source for Street Lighting in Hebron/ Palestine Using GSM Technology — shares topic coverage
- PIC 18F4550 Controlled Solar Panel Cooling System Using DC Hybrid — shares topic coverage
- Solar Energy: A Potential Source of Energy for Agricultural and Rural Development in Ghana — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.