Skip to content
Research Article Open access CC BY 4.0

Optimization of the Extraction Procedure of Apixaban from Dried Rat Plasma Spots

L. V. Aksenova, V. V. Koval, A. A. Chernonosov

Journal of Pharmaceutical Research International · pp. 6–14 · Published 20 Apr 2020

10.9734/jpri/2020/v32i530430

Abstract

Aims: Apixaban is an anticoagulant used to treat and prevent blood clots, as well as to prevent stroke in people with atrial fibrillation. The dried spot analyses, including dried blood spots and dried plasma spots, are used to simplify techniques for determining drug concentrations in blood and plasma. In this case, equipment with highly sensitive detector is required, for example, mass spectrometer, as well as a high level of drug extraction from the dried spot. In this work, apixaban extraction from dried plasma spots (DPS) was studied in order to determine the optimal parameters of the extraction method. Study Design: Short Research Articles. Place and Duration of Study: Core Facility of Mass Spectrometric Analysis, Institute of Chemical Biology and Fundamental Medicine SB RAS, between September 2019 and February 2020. Methodology: The organic extraction method was chosen for evaluation as the most suitable for LC-MS assay. Several parameters: percentage of organic solvent, presence or absence of 0.1% formic acid (FA), time, volume and temperature of extraction were investigated to find the best combination for recovery of apixaban from DPS for further LC-MS analysis. Results: The results showed that the main influence on the extraction is the composition of the solvent, volume of solvent, as well as temperature and time of extraction. Pure acetonitrile is the worst solvent for extracting apixaban from DPS. Solvents: MeOH:H2O (100:0, v: v), MeOH: 0.1% FA in H2O (80:20, v:v), ACN: 0.1% FA in H2O (90:10, v:v) or ACN:MeOH (90:10, v:v) provide better recovery of apixaban. The optimum extraction parameters were as follows: 90% acetonitrile concentration, extraction temperature of 40°C, extraction time of 15 min, and solvent volume of 100 μL Conclusion: For the extraction of apixaban from DPS, subject to further analysis by LC-MS, the most suitable solvent is 90% acetonitrile under the conditions described above.

Dried plasma spot DPS DBS apixaban LC-MS/MS extraction.

Cited by 1

Article metrics

Real usage data collected on this platform.

6

Page views

0

PDF downloads

0

Outbound clicks

1

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.