Skip to content
Research Article Open access CC BY 4.0

Mobile-bearing Dislocation of Unicompartmental Knee Arthroplasty after Stroke Successfully Treated with Total Knee Arthroplasty: A Case Report

Hendy Sujanto, Made Wahyu Mahatma Tanaya, Agus Eka Wiradiputra

Asian Journal of Orthopaedic Research · pp. 759–765 · Published 8 Oct 2026

10.9734/ajorr/2026/v9i2297

Abstract

Background: Unicompartmental knee arthroplasty (UKA) is an established treatment for isolated compartment osteoarthritis, offering rapid recovery and preserved kinematics. Bearing dislocation is a recognised mode of failure of mobile-bearing designs, and neuromuscular compromise, such as that associated with stroke, is a particularly important risk factor for recurrent failure. Presentation of Case: A 51-year-old man underwent medial UKA of the right knee for medial-compartment osteoarthritis. In the early postoperative period, he sustained an acute ischaemic (non-haemorrhagic) stroke. Approximately one month after the index procedure, he developed bearing dislodgement with loosening, managed with polyethylene insert exchange using a thicker bearing. One month after revision, he again presented with morning-onset pain, and radiographs demonstrated recurrent dislodgement of the insert. Given the recurrent failure on a background of post-stroke neuromuscular dysfunction, conversion to total knee replacement (TKR) was undertaken, with radiographs confirming a well-positioned arthroplasty construct. Discussion: Recurrent mobile-bearing dislodgement after UKA in a patient with new-onset hemiparesis reflects the impact of altered muscle tone, proprioception, and gait on a ligament-dependent implant. Conclusion: Early conversion to a more constrained TKR construct should be considered in preference to repeated isolated insert exchange when neuromuscular compromise drives recurrent bearing failure.

Unicompartmental knee arthroplasty mobile bearing dislocation total knee replacement stroke hemiparesis revision arthroplasty

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

4

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.