Development of ZrO2-Coated SPME Fibers for Detecting Benzotriazole Ultraviolet Filters in Water Samples
Chemical Science International Journal · pp. 155–162 · Published 2 Dec 2024
10.9734/CSJI/2024/v33i6934Abstract
In this study, the zirconium dioxide nanoparticles (ZrO2NPs) were coated on the surface of stainless steel (SS) by cyclic voltammetry (CV) as solid phase microextraction fiber coating for detection of the benzotriazole ultraviolet filters (BUvFs) in different real water samples. The composition and images of the new SS@ZrO2NPs fiber were characterized by scanning electron microscopy (SEM). The extraction capability of SS@ZrO2NPs fiber was investigated for the enrichment and detection of benzotriazole ultraviolet filters (BUvFs) phthalate acid esters (PAEs) and polycyclic aromatic hydrocarbons (PAHs) coupled with HPLC. The fabricated SS@ZrO2NPs fiber showed excellent extraction selectivity and good extraction capability for BUvFs. Under the optimized conditions, the SS@ZrO2NPs-SPME method presented linear ranging from 0.15 to 200 µg/L with correlation coefficients of higher than 0.9982. Moreover the limits of detection (LODs) varied from 0.020 µg/L to 0.138 µg/L. Relative standard deviations (RSDs) with single fiber were below 7.78% and 8.91% for intra-day and inter-day measurements, respectively. The developed method was used to the detection of trace BUvFs in different real water samples.
Cited by 0
No indexed citations yet.
Related research
- Pesticide Residues Monitoring of Organophosphorus and Carbamates in Grapes in Three Egyptian Governorates — shares topic coverage
- Efficiency of Solvatic Sorption Model for Predicting the Retention in Multi-step Gradient RP-LC with Different Stationary Phases — shares topic coverage
- Relative Analysis of Gallic-Acid, Theobromine, Theophylline, and Caffeine Content among 12 Bangladeshi Tea Genotypes Using Reversed-Phase Liquid Chromatography — shares topic coverage
- Prediction of Retention in Gradient Reversed-Phase Liquid Chromatography for Phenyl Isothiocyanate-Derivatives of Amino Acids — shares topic coverage
- A 100% Water Mobile Phase HPLC-PDA Analysis of Tetracycline Antibiotics — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.