Skip to content
Research Article Open access CC BY 3.0

Measuring Cranial Soft Tissue Thickness with MRI or Force-Compensated Tracked Ultrasound

Floris Ernst, Ralf Bruder, Tobias Wissel, Patrick Stüber, Achim Schweikard

Journal of Advances in Medicine and Medical Research · pp. 937–948 · Published 28 Oct 2013

10.9734/BJMMR/2014/6822

Abstract

Aims: A new approach to patient tracking in cranial stereotactic radiosurgery relies on contact-free localisation of the cranial bone. It requires accurate information about the soft tissue thickness on the patient's forehead, which in this work is measured using two independent modalities: magnetic resonance imaging (MRI) and force-compensated tracked ultrasound. Methodology: High resolution MRI scans and ultrasound data of the forehead were recorded and the soft tissue thickness was extracted. The datasets were registered using the iterative closest point algorithm with high accuracy (RMS error < 0.5 mm after artefacts from data acquisition were removed). Tissue deformation was analysed using a robotic setup with force control where the ultrasound transducer was pressed against the skin. Results: The force compensation setup showed that a tissue compression factor of 0.75 can be assumed for typically applied forces of 7-10N. This factor was confirmed by comparing histograms of soft tissue thickness. Comparing soft tissue thickness as measured by MRI and ultrasound showed a mean error of 0.14mm and a standard deviation of 0.87mm. Conclusion: We could show that, using MRI as a ground truth, data from 2D ultrasound can be compensated for pressure and can also be used to generate realistic values of soft tissue thickness.

Cranial radiotherapy force-compensated ultrasound soft tissue thickness motion management.

Cited by 4

The Influence of Age and Gender on Forehead Soft Tissue Thickness: A Magnetic Resonance Imaging-Based Study

Cagri Cakmakoglu, Grzegorz Kwiecien, Layne N. Raborn · Aesthetic Plastic Surgery · 2025

Showing 2 of 4 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

4

Page views

0

PDF downloads

7

Outbound clicks

4

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.