Skip to content
Research Article Open access CC BY 4.0

Measurement of Neck-Shaft Angle Using CT Scout View in Healthy Jordanian Adults - A Reliability and Agreement Study

Ibrahim Altubasi, Hayat Hamzeh, Mohammad Madi

Journal of Advances in Medicine and Medical Research · pp. 9–17 · Published 12 Sep 2020

10.9734/jammr/2020/v32i1630624

Abstract

Aims: To report estimates of the reliability and agreement of a new method for measuring the femoral Neck-shaft angle in the Jordanian population. The neck-shaft angle is an important anatomical indicator in orthopedics of the hip. While there are different approaches to measuring the neck-shaft angle in the literature, there is no agreement on the best technique used for measurement. CT scout view was used in this study to provide a promising alternative. Study Design: Observational reliability and agreement study. Places and Duration of the Study: Department of physiotherapy, school of rehabilitation science, University of Jordan and University of Jordan Hospital between March 2014 and October 2015. Methodology: Two independent raters calculated the neck-shaft angle on each hip of 50 pelvic CT scout images of healthy adults to determine inter-rater reliability. One rater performed the measurement twice to determine the intra-rater reliability. Intra-class correlation coefficients were used to examine relative reliability. The standard error of measurement (SEM) and 95% minimal detectable change (MDC) were calculated to examine absolute reliability.  Results: The mean value of all angle measurements was 131.3. Intra-class correlation coefficients were 0.726 and 0.63 for inter and intra-rater measurements respectively. SEM and MDC for inter-rater measurements were 2.69 and 7.46 respectively. For intra-rater measurements, they were 2.84 and 7.86 respectively. Conclusion: The new method proposed in this study for measuring the neck-shaft angle showed good reliability and small measurement error.

Neck-shaft angle reliability CT scout images standard error of measurement minimal detectable change.

Cited by 2

Computed tomography reference values estimation for femoral neck shaft angle in Egyptian healthy adults of both sexes

Medhat Ibraheem Mohammad Ahmad, Marina Talaat Bushra, Ahmed Talat Galal · Egyptian Journal of Radiology and Nuclear Medicine · 2023

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

2

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.