Skip to content
Research Article Open access CC BY 3.0

Macular Thickness Measurement via Heidelberg Spectralis SD-OCT in Pediatric Patients

Ihsan Yilmaz, Abdullah Ozkaya, Yalcin Karakucuk, Irfan Perente, Ahmet Taylan Yazici

Ophthalmology Research: An International Journal · pp. 384–390 · Published 20 Jul 2014

10.9734/OR/2014/11758

Abstract

Aims: To determine the normative values of the macular thickness measurements via spectral-domain optical coherence tomography (SD-OCT) in healthy pediatrics. Study Design:  Prospective study. Place and Duration of Study: Beyoglu Eye Training and Research Hospital. Department of Retina, between November 2013 and May 2014. Methodology: Sixty eyes of 30 healthy pediatric patients (20 females, 10 males) were included in this prospective study. Macular thickness measurements were performed via Spectralis SD-OCT. The average retinal thicknesses of the nine macular sectors as defined by the Early Treatment Diabetic Retinopathy Study and central macular volume were recorded. Results: The mean age was 10.8±3.1 years (range 6-15). The mean central macular thickness was 261±27μm (range 223-434). The mean central volume was 8.66±0.32mm3 (range 8.01-9.54). The mean thickness was 342±13μm for superior inner, 327±15μm for temporal inner, 341±22μm for inferior inner, 339±20μm for nasal inner, 300±11μm for superior outer, 286±15μm for temporal outer, 291±11μm inferior outer, 315±23μm for nasal outer segment. Conclusion: The means and normative reference ranges are provided for Spectralis OCT in healthy pediatrics, between 6-15 years old, and this values can be used as a standard to compare those of children suspected of having retinal or optic nerve abnormalities.  

Macular thickness optical coherence tomography SD-OCT normative data

References (23)

  1. 1 Optical Coherence Tomography [DOI]
  2. 2 Retinal thickness decreases with age: an OCT study [DOI]
  3. 3 High-Definition and 3-dimensional Imaging of Macular Pathologies with High-speed Ultrahigh-Resolution Optical Coherence Tomography [DOI]
  4. 4 COMPARISON OF SPECTRAL/FOURIER DOMAIN OPTICAL COHERENCE TOMOGRAPHY INSTRUMENTS FOR ASSESSMENT OF NORMAL MACULAR THICKNESS [DOI]
  5. 5 Comparison of Macular Thickness Measurements between Time Domain and Spectral Domain Optical Coherence Tomography [DOI]
  6. 6 Normative Reference Ranges for the Retinal Nerve Fiber Layer, Macula, and Retinal Layer Thicknesses in Children [DOI]
  7. 7 Evaluation of Time Domain and Spectral Domain Optical Coherence Tomography in the Measurement of Diabetic Macular Edema [DOI]
  8. 8 Evaluation of the Nerve Fiber Layer and Macula in the Eyes of Healthy Children Using Spectral-Domain Optical Coherence Tomography [DOI]
  9. 9 Error Correction and Quantitative Subanalysis of Optical Coherence Tomography Data Using Computer-Assisted Grading [DOI]
  10. 10 Spectral-Domain Optical Coherence Tomography Use in Macular Diseases: A Review [DOI]
  11. 11 Multicenter Spanish study of spectral‐domain optical coherence tomography in normal children [DOI]
  12. 12 MACULAR THICKNESS MEASUREMENTS IN NORMAL EYES WITH TIME-DOMAIN AND FOURIER-DOMAIN OPTICAL COHERENCE TOMOGRAPHY [DOI]
  13. 13 Macular Thickness Measurements in Normal Eyes Using Spectral Domain Optical Coherence Tomography [DOI]
  14. 14 Spectral domain optical coherence tomography in children: normative data and biometric correlations [DOI]
  15. 15 Comparison of Macular Thickness Between Cirrus HD-OCT and Stratus OCT [DOI]
  16. 16 Reproducibility of Optical Coherence Tomography Measurements in Children [DOI]
  17. 17 Discriminating ability of spectral domain optical coherence tomography in different stages of glaucoma [DOI]
  18. 18 Repeatability of Retinal Thickness Measurements Between Spectral-Domain and Time-Domain Optical Coherence Tomography Images in Macular Disease [DOI]
  19. 19 Macular edema in the era of spectral-domain optical coherence tomography [DOI]
  20. 20 Spectral- and time-domain optical coherence tomography measurements of macular thickness in young myopic eyes [DOI]
  21. 21 Reproducibility of Peripapillary Retinal Nerve Fiber Layer Thickness Measured by Spectral Domain Optical Coherence Tomography in Pseudophakic Eyes [DOI]
  22. 22 A Formula to Predict Spectral Domain Optical Coherence Tomography (OCT) Retinal Nerve Fiber Layer Measurements Based on Time Domain OCT Measurements [DOI]
  23. 23 1 Optical Coherence Tomography [DOI]

Cited by 4

Agreement and differences between macular values in children using two types of spectral optical coherence tomography

J.M. Ruiz Caro Larrea, L. Cabrejas Martínez, M.A. Alonso Peralta · Archivos de la Sociedad Española de Oftalmología (English Edition) · 2021

Showing 1 of 4 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

62

Page views

0

PDF downloads

39

Outbound clicks

4

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.