Skip to content
Research Article Open access CC BY 4.0

The Significance of Time Step Size in Simulating the Thermal Performance of Buildings

Aiman Albatayneh, Dariusz Alterman, Adrian Page, Behdad Moghtaderi

Advances in Research · pp. 1–12 · Published 12 Sep 2015

10.9734/AIR/2015/20223

Abstract

The determination of the internal air temperature of a building is pivotal to its design in the determination of heating and cooling loads and the assessment of the thermal comfort for the occupants. Autodesk CFD analysis is one of many application programs which can assist in calculating building internal air temperatures and it is expected that using a smaller time step size can provide more accurate results but long term simulations for complex building analysis is significantly lengthening computing time. To solve these issues a larger time step can be used. This speeds up the computing time and also results in a higher predicted (and more realistic) internal temperature fluctuation range. This is reported in this paper, where the larger time scale technique is used with an average capacity personal computer (PC) machines to perform the simulations. This fast Computational Fluid Dynamics (CFD) simulation method is used to simulate the thermal performance of a series of existing housing test modules constructed using a range of walling systems. The performance of the proposed computing technique is assessed by comparing the internal air temperature of each building at the floor level. To find the time step which gives the most accurate simulation of the measured internal air temperature, CFD simulations were carried out for various time steps (15, 30, 60, 80, 100, 120, 150, 180 minutes); it was found that 80 and 100 minute time steps gave the most accurate representation of the real fluctuation. The fastest simulation with the most accurate results was for a 80/100 time step where more than 87% of the results fell within a 3°C range compared to the real data. This also required only 1% of the computing time compared to a 1 minute time step.

Thermal performance building enclosure CFD analysis long term simulations

Cited by 20

Discrepancies in Peak Temperature Times using Prolonged CFD Simulations of Housing Thermal Performance

Aiman Albatayneh, Dariusz Alterman, Adrian Page · Energy Procedia · 2017

Analysis on impact of energy efficient techniques to enhance the building performance

Prerna Sharma, V.R. Prasathkumar, R. Senthil Kumar · IOP Conference Series: Materials Science and Engineering · 2020

Short Overview of Energy Potential Trials and Triumphs of Institution

Adedapo S. Okunade, Benjamin E. Anyaegbuna, Ojo S. Fayomi · 2024 International Conference on Science, Engineering and Business for Driving Sustainable Development Goals (SEB4SDG) · 2024

The Significance of the Orientation on the Overall buildings Thermal Performance-Case Study in Australia

Aiman Albatayneh, Dariusz Alterman, Adrian Page · Energy Procedia · 2018

Improving thermal comfort in mosques of hot-humid climates through passive and low-energy design strategies

Nabeeha Amatullah Azmi, Azhaili Baharun, Müslüm Arıcı · Frontiers of Architectural Research · 2023

A review of reflected sunlight from buildings: problems and challenges

Juan Yi, Zhen Tian, Daniel Rüdisser · Sustainable Cities and Society · 2024

The Significance of Sky Temperature in the Assessment of the Thermal Performance of Buildings

Aiman Albatayneh, Dariusz Alterman, Adrian Page · Applied Sciences · 2020

The Significance of Building Design for the Climate

Aiman Albatayneh, Dariusz Alterman, Adrian Page · Environmental and Climate Technologies · 2018

Examining the Thermal Properties of Full-Scale Test Modules on the Overall Thermal Performance of Buildings

Aiman Albatayneh, Dariusz Alterman, Adrian Page · Advances in Science, Technology & Innovation · 2021

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

20

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.