Skip to content
Research Article Open access CC BY 4.0

Laboratory Calibration of Capacitance-Based Soil Moisture Sensor to Monitor Subsurface Soil Moisture Movement in Laterite Soil

Jyothy Narayanan, K. K. Sathian

International Journal of Plant & Soil Science · pp. 137–147 · Published 3 Aug 2021

10.9734/ijpss/2021/v33i1730558

Abstract

Subsurface soil moisture movement in the unsaturated zone plays a critical role in the replenishment of groundwater table. This comprehension can be vital for the terrain with lateritic soil followed by the charnockite bedrock system. The conventional techniques to determine the subsurface soil moisture and its movement is cumbersome owing to high cost, large scale time consumption, field drudgery and greater possibility of manual errors. Among many other modern technologies for the measurement of volumetric water content, capacitance-based moisture sensors are capable and less expensive, thus, making them highly suitable for the research scholars worldwide. The study involves the use of TEROS 12 moisture sensors. The capacitance-based sensor TEROS 12, equipped with advanced soil moisture technique curtails the constraints in the conventional technique of soil moisture assessment and can provide precise measurements if suitably calibrated for the site specific soils. The study involves a soil specific calibration of TEROS 12 moisture sensor which was performed for the laterite soil to incorporate the sensor with the automated soil moisture monitoring system. The reliability of the sensor TEROS 12 was assessed by comparing its moisture measurements with that of the gravimetric method. The calibration was performed for three TEROS 12 moisture sensors in order to monitor the interflow at three varying soil depths in the vadose zone. The R2 values obtained from the calibration of sensors at depths of 0-0.4 m, and 0.8-1.2 m were 0.996, 0.994 and 0.992 respectively. Further, during validation it was found that the new measurements coordinated with the gravimetric measurements to a greater extent and increased the preciseness as compared to that of uncalibrated values of moisture contents, thereby establishing TEROS 12 capacitance-based sensor as a reliable and cost effective moisture sensor.

Calibration capacitance-based sensor TEROS 12 interflow soil moisture movement

Cited by 2

Predicting Water Content and Saturation in Mine Tailings with an Electromagnetic Soil Moisture Sensor

Garret M. Martin, Christopher A. Bareither · Mine Water and the Environment · 2024

Emerging technologies for efficient water use in agriculture: A review of current trends and future directions

Uttam Biswas Antu, Md. Saiful Islam, Sujat Ahmed · Journal of Water Process Engineering · 2024

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

2

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.