Skip to content
Research Article Open access CC BY 4.0

Application and Testing of a Laboratory Biotower Septic Tank System for Effluent Treatment - A Laboratory Study

Klaus Dölle, Simon Lex

Asian Journal of Advanced Research and Reports · pp. 8–17 · Published 28 Jul 2022

10.9734/ajarr/2022/v16i930494

Abstract

A laboratory biotower septic tank system was designed, installed, started up with unfiltered wastewater during a 9-day start-up phase, and operated at a hydraulic retention time of 5-, 15-, and 20 days with filtered waste water and 5-, 10-, and 15 days for liquid cow manure. The system was operated at a laboratory room temperature of 23.0±0.5°C (73.4 ± 0.9°F). The system had an influent pH of 7.5 ±0.1 and a slightly higher pH of 8.0±0.1 for the effluent for filtered wastewater, and an influent pH of 7.3 ±0.1 and a slightly increased effluent pH of 7.5  ± 0.1 for the operation with liquid cow manure. This research showed that the system is able to achieve an effluent chemical oxygen demand level between 17 ±1 mg/l, and 19 ±1 mg/l for a hydraulic retention time between 5-, and 20 days for filtered waste water, and between 23 ±1 mg/l and 32 ±3 mg/l for a hydraulic retention time between 5-, and 15 days for liquid cow manure at highly varying influent chemical oxygen demand levels between 25 ±1 mg/l and 74 ±15 mg/l and 293 ±46 mg/l to 335 ±14 mg/ for filtered wastewater and liquid cow manure respectively. The Total solids content in the effluent of the system showed an increase for the filtered wastewater and liquid cow manure influent with increasing hydraulic retention rate from of 55 mg/l to 71 mg/l and from 25 mg/l to 53 mg/l respectively. Total suspended solids for both, the filtered wastewater and the liquid cow manure was below the 4mg/l mark, except for the liquid cow manure 5-day hydraulic retention rate which had a value of 20 mg/l.

Biotower cow manure contaminants septic system sewage wastewater wastewater treatment

Cited by 1

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

1

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.