Skip to content
Research Article Open access CC BY 4.0

Optimized Hexagonal Photonic Crystal Fibre Sensor for Glucose Sensing

Md. Bellal Hossain, Etu Podder, Apurba Adhikary, Abdullah- Al-Mamun

Advances in Research · pp. 1–7 · Published 26 Jan 2018

10.9734/AIR/2018/38972

Abstract

Aims: This paper presents an optimised hexagonal photonic crystal fibre (PCF) geometry for investigation of relative sensitivities for 20%, 30%, 40%, 50% and 60% of glucose solution in water at a wavelength ranging from 1200 nm to 1600 nm. This work also shows an active area and confinement loss variation of the optimised hexagonal PCF when the core is filled with different concentrations of glucose solution. Study Design:  Here, optimised hexagonal photonic crystal fiber (PCF) geometry is chosen where COMSOL Multiphysics software is used for simulation. Place and Duration of Study: Department of Electronics and Communication Engineering at Khulna University, Khulna-9208, Bangladesh and Study duration was between March 2017 and December 2017. Methodology: At first, 20%, 30%, 40%, 50% and 60% of glucose solution in water with different refractive indexes are inserted through the core of the modified Hexagonal PCF. Then, the simulation is done by varying wavelength from 1200 nm to 1600 nm. Here, Comsol Multiphysics is used for simulation and MATLAB is used to plot the desired optical properties of the proposed PCF geometry. Results: From this work, the relative sensitivities are obtained approximately 28.6, 33.09, 36.97, 40.37, 44.81 in percentage at wavelength 1200 nm and 35.27, 37.63, 41.15, 44.98, 47.87 in percentage at wavelength 1600 nm for 20%, 30%, 40%, 50% and 60% of glucose solution in water respectively. Again, the effective areas are found approximately 16.306 μm2, 17.285 μm2, 18.207 μm2, 19.209 μm2, 19.729 μm2 at wavelength 1200 nm and 18.823 μm2, 19.495 μm2, 20.21 μm2, 20.739 μm2, 20.954 μm2 at wavelength 1600 nm for 20%, 30%, 40%, 50% and 60% of glucose solution in water respectively. The confinement losses are approximately 2.1×10-8 dB/Km, 0.78×10-8 dB/Km, 0.15×10-8 dB/Km for 20%, 30%, and 40% of glucose solution in water respectively at wavelength 1500 nm but for 50% and 60% of glucose solution, the confinement loss is approximately zero from 1200 nm to 1600 nm. Conclusion: High sensitive Glucose sensor is achieved with optimised Hexagonal PCF structure which was the main target of this research.  

Photonic crystal fiber relative sensitivity effective area confinement loss COMSOL multiphysics

Cited by 40

Multi analyte detection based on D-shaped PCF sensor for glucose concentrations sensing

Ammar M. Tuaimah, S. R. Tahhan, Hanan J. Taher · Optical and quantum electronics · 2023

Design and simulation of photonic crystal fibre sensor for harmful chemicals detection in polycarbonate plastics

Abdul Mu’iz Maidi, R. Salam, M. Kalam · Optical and quantum electronics · 2023

Highly Sensitive Biosensor based on a Microstructured Photonic Crystal Fibre for Alcohol Sensing

Ang Shi, Abdul Mu'iz Maidi, S. Kaijage · Results in Optics · 2023

Performance analysis of slotted rectangular photonic crystal fiber structures in terahertz waveguidance

A. Linsie, Sachin Kumar, Shyamal Mondal · Optical Engineering: The Journal of SPIE · 2022

Theoretical Considerations of Photonic Crystal Fiber with All Uniform-Sized Air Holes for Liquid Sensing

Abdul Mu’iz Maidi, Pg Emeroylariffion Abas, P. I. Petra · Photonics · 2021

Hollow-core high-sensitive photonic crystal fiber for liquid-/gas-sensing applications

R. Senthil, Utkarsh Anand, Prabu Krishnan · Applied Physics A · 2021

Design and Investigation of a High-Sensitivity PCF Sensor for the Detection of Sulfur Dioxide

S. Mohamed Nizar, Elizabeth Caroline, Prabu Krishnan · Plasmonics · 2021

Fiber Optic Sensors: A Review for Glucose Measurement

J. L. Cano Pérez, J. Gutiérrez-Gutiérrez, Christian Perezcampos Mayoral · Biosensors · 2021

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

40

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.