Skip to content
Research Article Open access CC BY 2.0

Heat Transfer and Friction Factor Correlations for Rectangular Solar Air Heater Duct Having 60° Inclined Continuous Discrete Rib Arrangement

Thakur Sanjay Kumar, Vijay Mittal, N. S. Thakur, Anoop Kumar

Current Journal of Applied Science and Technology · pp. 67–93 · Published 30 Mar 2011

10.9734/BJAST/2011/265

Abstract

The heat transfer coefficient between the absorber plate and air can be considerably increased by using artificial roughness on the underside of the absorber plate of the solar air heater. An experimental study has been carried out for enhancement of heat transfer coefficient of a solar air heater having roughened air duct provided with artificial roughness in the form 60° inclined discrete rib. Increment in friction factor by provided with such artificial roughness element has also been studied. The effect of system parameters such as relative roughness height (e/D), relative roughness pitch (P/e) and relative gap position (d/W) have been studied on Nusselt number (Nu) and friction factor (f) with relative gap width (g/e) 1 and Reynolds number (Re) varied from 4105 to 20526. Considerably enhancement in heat transfer coefficient has been achieved with such roughness element. Using experimental data correlations for Nusselt number and friction factor have also been developed for such solar air heaters, which gives a good agreement between predicted values and experimental values of Nusselt number and friction factor.  

Solar air heater artificial roughness Nusselt number Friction factor

Cited by 15

Performance analysis of solar air heater duct roughened with multigap V-down ribs combined with staggered ribs

Narinderpal Singh Deo, Subhash Chander, J.S. Saini · Renewable Energy · 2016

Experimental and CFD-based thermal performance prediction of solar air heater provided with right-angle triangular rib as artificial roughness

Vipin B. Gawande, A. S. Dhoble, D. B. Zodpe · Journal of the Brazilian Society of Mechanical Sciences and Engineering · 2015

Revisiting the Effect of Rib Roughness on the Performance of Solar Air Heater

Neeraj Kumar Nagayach, Kanishk Sharma, Yogesh Agrawal · E3S Web of Conferences · 2023

Enhancement of Solar Collector Thermal Performance using Louvered Absorber

Louy Qoaider, Mays Nasir Shaeli, Jalal M. Jalil · 2017 International Renewable and Sustainable Energy Conference (IRSEC) · 2017

Heat and fluid flow characteristics of roughened solar air heater ducts – A review

Anil Kumar, R.P. Saini, J.S. Saini · Renewable Energy · 2012

Effect of roughness geometries on heat transfer enhancement in solar thermal systems – A review

Vipin B. Gawande, A.S. Dhoble, D.B. Zodpe · Renewable and Sustainable Energy Reviews · 2014

Experimental and CFD-based thermal performance prediction of solar air heater provided with chamfered square rib as artificial roughness

Vipin B. Gawande, A. S. Dhoble, D. B. Zodpe · Journal of the Brazilian Society of Mechanical Sciences and Engineering · 2015

A study of heat transfer enhancement in a new solar air heater having circular type turbulators

Adem Acır, İsmail Ata · Journal of the Energy Institute · 2016

Heat transfer and fluid flow behaviour of a rectangular duct roughened with V-ribs with symmetrical gaps

Rajesh Maithani, J. S. Saini · International Journal of Ambient Energy · 2015

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

15

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.