Heat Transfer and Friction Factor Correlations for Rectangular Solar Air Heater Duct Having 60° Inclined Continuous Discrete Rib Arrangement
Thakur Sanjay Kumar, Vijay Mittal, N. S. Thakur, Anoop Kumar
Current Journal of Applied Science and Technology · pp. 67–93 · Published 30 Mar 2011
10.9734/BJAST/2011/265Abstract
The heat transfer coefficient between the absorber plate and air can be considerably increased by using artificial roughness on the underside of the absorber plate of the solar air heater. An experimental study has been carried out for enhancement of heat transfer coefficient of a solar air heater having roughened air duct provided with artificial roughness in the form 60° inclined discrete rib. Increment in friction factor by provided with such artificial roughness element has also been studied. The effect of system parameters such as relative roughness height (e/D), relative roughness pitch (P/e) and relative gap position (d/W) have been studied on Nusselt number (Nu) and friction factor (f) with relative gap width (g/e) 1 and Reynolds number (Re) varied from 4105 to 20526. Considerably enhancement in heat transfer coefficient has been achieved with such roughness element. Using experimental data correlations for Nusselt number and friction factor have also been developed for such solar air heaters, which gives a good agreement between predicted values and experimental values of Nusselt number and friction factor.
Cited by 15
V.B. Gawande, A.S. Dhoble, D. B. Zodpe · Australian Journal of Mechanical Engineering · 2018
Kapil Chaudhri, J. L. Bhagoria, Vikash Kumar · Journal of Thermal Analysis and Calorimetry · 2024
Ismail Ata, Ramazan Çakıroğlu, Adem Acir · Heat Transfer Research · 2023
Adem Acır, İsmail Ata, Mehmet Emin Canlı · Experimental Thermal and Fluid Science · 2016
Tabish Alam, Karmveer · Renewable Energy Technologies · 2022
Related research
- Variable Heat and Mass Transfer Boundary on an Unsteady MHD Flow through a Porous Medium over an Infinite Vertical Plate — shares topic coverage
- Determination of Friction Factor over a Pool Reach by Double-average Method — shares topic coverage
- Parametric Analysis of MEMS – Based Heat Exchanger with Different Test Fluids — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
15
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.