Initial Insight to Effect of Exercise on Maximum Pressure in the Left Ventricle Using 2D Fluid-Structure Interaction Model
Arezoo Khosravi, Hamidreza Ghasemi Bahraseman, Ali Vazifehdoost Saleh, Davood Kazemi-Saleh
Annual Research & Review in Biology · pp. 2867–2883 · Published 12 May 2014
10.9734/ARRB/2014/7229Abstract
Aims: Study of maximum pressure in the left ventricle (MPLV) has already been a challenging aspect of clinical diagnosis. The aim of this study was to propose a model to estimate the MPLV for a healthy subject based on cardiac outputs measured by echo-Doppler (non-invasive) and catheterization (invasive) techniques at rest and during exercise. Study Design and Methodology: Blood flow through the aortic valve was measured by Doppler flow echocardiography. The aortic valve geometry was then calculated by echocardiographic imaging. A Fluid-Structure Interaction (FSI) simulation was performed, using an Arbitrary Lagrangian-Eulerian (ALE) mesh. Boundary conditions were defined as pressure loads on ventricular and aortic sides during ejection phase. The FSI modelling was applied to determine a numerical relationship between the cardiac output to left ventricular and aortic diastolic pressures. These relationships enable the prediction of pressure loads from cardiac outputs measured by invasive and non-invasive clinical methods. Results: Peak ventricular systolic pressure calculated from cardiac output of Doppler method, Fick oximetric and Thermodilution methods led to a 82.1%, 95.6% and 147% increment throughout exercise, respectively. The mean slopes obtained from curves of ventricular systolic pressure based on Doppler, Fick oximetric and Thermodilution methods are 1.27, 1.85 and 2.65mmHg.min, respectively. Our predicted Fick-MPLV values were 8% to 19% lower, 17% to 25% lower for Thermodilution-MPLV and 57% to 73% lower for Doppler-MPLV values when compared to clinical reports. Conclusion: Predicted results are in good agreement with values in the literature. The method, however, requires validation by additional experiments, comprising independent quantifications of MPLV. Since flow depends on the pressure loads, measuring more accurate intraventricular pressures helps to understand the cardiac flow dynamics for better clinical diagnosis. Furthermore, the method is noninvasive, safe, cheap and practical. As clinical Fick-measured values have been known to be more accurate, our Fick-based prediction could be the most applicable.
References (40)
- 1 An arbitrary lagrangian-eulerian finite element method for transient dynamic fluid-structure interactions [DOI]
- 2 Numerical solution of the quasilinear poisson equation in a nonuniform triangle mesh [DOI]
- 3 A three-dimensional computational analysis of fluid–structure interaction in the aortic valve [DOI]
- 4 Non‐invasive assessment of cardiac output during exercise in healthy young humans: comparison between Modelflow method and Doppler echocardiography method [DOI]
- 5 A Stability Analysis for the Arbitrary Lagrangian : Eulerian Formulation with Finite Elements
- 6 A computational fluid-structure interaction analysis of a fiber-reinforced stentless aortic valve [DOI]
- 7 A multiscale computational comparison of the bicuspid and tricuspid aortic valves in relation to calcific aortic stenosis [DOI]
- 8 Finite-element-based computational methods for cardiovascular fluid-structure interaction [DOI]
- 9 Mouse isolated perfused heart: Characteristics and cautions [DOI]
- 10 Noninvasive estimation of transmitral pressure drop across the normal mitral valve in humans: importance of convective and inertial forces during left ventricular filling [DOI]
- 11 Simultaneous determination of the accuracy and precision of closed-circuit cardiac output rebreathing techniques [DOI]
- 12 Evaluation of a fictitious domain method for predicting dynamic response of mechanical heart valves [DOI]
- 13 Aortic valve leaflet mechanical properties facilitate diastolic valve function [DOI]
- 14 Evaluation of a transient, simultaneous, arbitrary Lagrange–Euler based multi-physics method for simulating the mitral heart valve [DOI]
- 15 Nonobstructive left ventricular ejection pressure gradients in man. [DOI]
- 16 Computer and Experimental Modelling of Blood Flow through the Mitral Valve of the Heart [DOI]
- 17 Finite-element-method (FEM) model generation of time-resolved 3D echocardiographic geometry data for mitral-valve volumetry [DOI]
- 18 Effect of exercise on blood flow through the aortic valve: a combined clinical and numerical study [DOI]
- 19 Invasive and non-invasive methods for cardiac output measurement
- 20 Subject-specific knee joint model: Design of an experiment to validate a multi-body finite element model [DOI]
- 21 Two-Dimensional FSI Simulation of Closing Dynamics of a Tilting Disk Mechanical Heart Valve [DOI]
- 22 Instantaneous diastolic transmitral pressure differences from color Doppler M mode echocardiography [DOI]
- 23 Pressure gradients across bileaflet aortic valves by direct measurement and echocardiography [DOI]
- 24 The Fluid Mechanics of Heart Valves [DOI]
- 25 Combining numerical and clinical methods to assess aortic valve hemodynamics during exercise [DOI]
- 26 Effects of ischemic training on leg exercise endurance [DOI]
- 27 A Simple Method for Contact modelling in an Arbitrary frame of Reference within multi-Physics Software [DOI]
- 28 Direct Comparison between Brachial Pressure Obtained by Oscillometric Method and Central Pressure Using Invasive Method [DOI]
- 29 Computational Evaluation of Intraventricular Pressure Gradients Based on a Fluid-Structure Approach [DOI]
- 30 NUMERICAL SIMULATION OF 3D FLUID-STRUCTURE INTERACTION USING AN IMMERSED MEMBRANE METHOD [DOI]
- 31 Left intraventricular pressure-impedance diagrams (DPZ) to assess cardiac function. Part II: determination of end-systolic loci.
- 32 Maximum Cardiac Output During Incremental Exercise by First-pass Radionuclide Ventriculography [DOI]
- 33 Oxygen Fick and modified carbon dioxide Fick cardiac outputs [DOI]
- 34 Space and time dependency of inertial and convective contribution to the transmitral pressure drop during ventricular filling [DOI]
- 35 Prediction of left ventricular pressure in infants with aortic stenosis. [DOI]
- 36 Left ventricular performance and blood catecholamine levels in the isolated heart [DOI]
- 37 FINITE ELEMENT ANALYSIS OF NON-LINEAR FLUID STRUCTURE INTERACTION IN HYDRODYNAMICS USING MIXED LAGRANGIAN-EULERIAN METHOD [DOI]
- 38 Determination of Stroke Volume and Cardiac Output During Exercise: Comparison of Two-Dimensional and Doppler Echocardiography, Fick Oximetry, and Thermodilution [DOI]
- 39 Deaths: Preliminary Data for 2001 [DOI]
- 40 Textbook of Medical Physiology. [DOI]
Cited by 2
A. Mehdizadeh · Journal of Biomedical Physics and Engineering · 2014
A. Ansari, Hamidreza Ghasemi Bahraseman, Morteza Mohssenzadeh · Engineering Solid Mechanics · 2019
Article metrics
Real usage data collected on this platform.
8
Page views
0
PDF downloads
0
Outbound clicks
2
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.