Optimization of Radiation Protection for Companions in Pediatric Chest Radiography
Luísa Vargas Cassol, Felipe de Bail, Thays Bandeira Rodrigues, Maurício Alves Müller, Rafael Rimoli Santos, Nataly Nogueira Favarin, Laura Pizarro Trojahn Nogueira, Thiago Victorino Claus
Physical Science International Journal · pp. 1–7 · Published 31 Jul 2024
10.9734/psij/2024/v28i5844Abstract
Aims: The objective of this study is to optimize the positioning of the companion during pediatric chest radiographic exams by analyzing the scattered radiation dose measured with an ionization chamber. Place and Duration of Study: The experimental study was conducted between February 2024 and April 2024, in the radiodiagnosis laboratory belonging to the Medical Physics and Radiology Technology courses at the Franciscan University (UFN) in the city of Santa Maria, Rio Grande do Sul. Methodology: A fixed conventional X-ray device and a phantom (simulating object) filled with 15 cm of water to represent a pediatric chest were used. The parameters of voltage (kV) and the product of current and time (mA.s) were kept constant. Measurements of the air KERMA (KAIR) were performed by positioning the dosimetric system at four points around the phantom (0º, 90º, 180º, and 270º), simulating the exposure conditions of the companion. Results: The results showed that the lowest radiation dose received by the companion at the gonadal level occurred at 90º around the table (cathode side), while the lowest dose at the lens level was at 270º (anode side). The highest dose at the gonadal level was observed at 180º, and the highest dose at the lens level was at 90º. Conclusion: It was concluded that the companion should position themselves on the anode side (270º), as the lens does not have lead protection, while protection is available for the rest of the body. This recommendation aims to optimize radiological safety for the companion.
Cited by 0
No indexed citations yet.
Related research
- Evaluation of the Influence on the Use of Additional Filtration in Pelvic Radiographic Examinations Using a Phantom Object — shares topic coverage
- Fe Kα Lines of MCG-6-30-15: Emission from Thin-torus Particles around a Kerr Black Hole — shares topic coverage
- Radioprotection Compliance Rules Study in Dakar's Hospitals, Senegal — shares topic coverage
- Measurement of Radioactivity Concentration in Pegmatite Rock Samples and Dose Assessment from Wamba in North Central Nigeria — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.