Skip to content
Research Article Open access CC BY 4.0

Impact of Seroma Volume Reduction on Dosimetry in Whole Breast Radiation Therapy: A Case Study and Adaptive Planning Considerations

Yen Cho Huang, Jih Hsiang Yeh, Chien Sheng Tsai

Journal of Advances in Medicine and Medical Research · pp. 410–416 · Published 15 Jul 2024

10.9734/jammr/2024/v36i75517

Abstract

Aims: To explore the impact of seroma volume reduction on dosimetry during whole breast radiation therapy (WBRT) and evaluate the significance of adaptive planning. Presentation of Case: A 71-year-old female with left breast invasive carcinoma underwent lumpectomy and radiotherapy. An initial CT (CT1) six weeks taken post-op showed a seroma cavity, and a second CT (CT2) five weeks later documented a 65% seroma volume reduction (from 217 c.c. to 75 c.c.). Five radiotherapy techniques were evaluated: two-field conventional, three-field conventional, forward IMRT, inverse IMRT, and VMAT. Inverse IMRT and VMAT achieved better high-dose coverage and reproducibility but had larger dose variations. They also showed higher maximum doses and increased hot spot volumes, indicating potential overdosage risks. Conventional techniques provided stable lower-dose coverage but less uniform high-dose distribution compared to IMRT and VMAT. Discussion: The significant reduction in seroma volume affected dosimetry, highlighting the importance of adaptive planning. In this case, daily KV and weekly MV imaging were used for alignment, but CBCT may better monitor seroma changes. Adaptive radiotherapy, repeated CT simulations, and CBCT are essential for effective treatment. Further research should focus on improving treatment precision through advanced imaging and radiotherapy technologies. Conclusion: This single WBRT case highlights the dosimetric impact of seroma reduction and the importance of imaging and adaptive strategies. Advanced techniques like inverse IMRT and VMAT improve precision but need careful IGRT monitoring. These findings emphasize the need for individualized adaptive planning considerations and further research to optimize protocols for managing seroma volume changes during WBRT.

Breast cancer radiation therapy seroma dosimetry breast-conserving treatment adaptive planning IGRT

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

9

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.