Skip to content
Research Article Open access CC BY 4.0

Idling and Short-circuit Analysis of a Three-phase Power Transformer Represented by a Scheme with Distributed Parameters and П line Scheme in the Electrical Network

N. Marković, S. Bjelić, F. Marković, U. Jakšić

Current Journal of Applied Science and Technology · pp. 22–37 · Published 29 Apr 2023

10.9734/cjast/2023/v42i94091

Abstract

Aims: The paper presents a simulation of a theoretical model of electromagnetic extreme regimes, idling and short circuit, in a three-phase power transformer. The main goal of this paper is to show in a quality way that the computer simulation of the obtained theoretical model using the software package MATLAB Simulink confirms the possibility of analyzing the extreme modes of transformers. Methodology: To solve the problem of the presence of a transformer as an element of power in the power system, the following are used: Analytical methods in which the transformer is presented as a network element - usually as a quadripole, numerical programming that includes dynamic programming and independent variables, and combined programming with integer values. In the process simulation on elements with given parameters and frequency, a comparison of the substitution schemes used so far in the theory of electric circuits is performed. The accuracy of these theoretical models can be confirmed by voltage and current diagrams in the adapted software package MATLAB Simulink. Conclusion: The presented theoretical model and the applied algorithm in the simulation are universal and can be used for different states in which a three-phase power transformer can be found. Problems that occur in the analysis of transient processes in electrical networks where the element is a transformer can be minimized using simulation methods. Changing any parameter in the electrical circuit requires a new calculation of the condition of the circuit from the very beginning due to the new initial conditions. Analytical methods combined with the simulation method were used in the research of extreme regimes, such as idling and short circuit. The verified simulation method realized using the adapted MATLAB Simulink program had a threefold purpose: to serve the calculation and simulation of quantities that can be obtained by testing or measuring, to establish the original algorithm and to verify the proposed method. Also, this type of simulation can replace the idle and short circuit test.

Simulation model electrical network three-phase power transformer power line quadripole

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.