FT-Raman Spectroscopy and PLS Regression for Quantitative Determination of Captopril in Tablet Powder; Effect of Different Preprocessing Methods
Ahmed Shawky, Ahmed Ibrahim, Maissa Y. Salem, Ahmed E. El Gindy
Chemical Science International Journal · pp. 24–37 · Published 4 Oct 2013
10.9734/ACSJ/2014/6087Abstract
Aims: This study was performed to develop a fast and simple method for the quantitative analysis of Captopril in tablet powder by FT-Raman Spectroscopy and PLS regression. The effect of different preprocessing methods on multivariate calibration was studied. Methodology: Four different preprocessing methods, namely mean center (MC), autoscale (AS), normalization (N1) and orthogonal signal correction (OSC) were applied to reduce the impact of sources of variability, such as instrument drift and sampling variability, correct for path length variation and increase the signal to noise ratio. PLS regression models were fitted and their predictive performance was evaluated by the root mean square error of prediction (RMSEP) and number of latent variables (LVs). Place and Duration of Study: School of Pharmacy, University of Maryland, between July to November 2012. Results: N1-AS combination (in this order) was found to give best results as it decreased the RMSEP by 15 % (from 0.92 to 0.77) with same number of latent variable used in the model (2 LVs). Other preprocessing methods have not yielded good results for this application. The results obtained by the proposed method were compared with those of the reported HPLC method. No significant difference has been observed regarding both accuracy and precision. Conclusion: FT-Raman Spectroscopy with PLS regression can be used as a reliable alternative for HPLC method, as it is faster and does not require sample pretreatment procedures.
References (16)
- 1 Partial least-squares methods for spectral analyses. 1. Relation to other quantitative calibration methods and the extraction of qualitative information [DOI]
- 2 Orthogonal signal correction of near-infrared spectra [DOI]
- 3 An evaluation of orthogonal signal correction applied to calibration transfer of near infrared spectra [DOI]
- 4 Simultaneous determination of captopril and hydrochlorothiazide in human plasma by reverse-phase HPLC from linear gradient elution [DOI]
- 5 An investigation of orthogonal signal correction algorithms and their characteristics [DOI]
- 6 Quantitative determination of captopril and prednisolone in tablets by FT-Raman spectroscopy [DOI]
- 7 Quantitative analysis of sulfathiazole polymorphs in ternary mixtures by attenuated total reflectance infrared, near-infrared and Raman spectroscopy [DOI]
- 8 Quantitative determination of diclofenac sodium and aminophylline in injection solutions by FT-Raman spectroscopy [DOI]
- 9 Chemometrics, why, what and where to next? [DOI]
- 10 Factors Affecting the Performance of Bench-Top Raman Spectrometers. Part I: Instrumental Effects [DOI]
- 11 Determination of captopril by high-performance liquid chromatography with direct electrogenerated chemiluminescence [DOI]
- 12 Factors Affecting the Performance of Bench—Top Raman Spectrometers. Part II: Effect of Sample [DOI]
- 13 Solid-state trans–cis isomerization of captopril determined by thermal Fourier transform infrared (FT-IR) microspectroscopy [DOI]
- 14 Spectral characteristic investigation on complex of Ni (II) with captopril and its analytical application [DOI]
- 15 The Merck Index: An Encyclopedia of Chemicals, Drugs, and Biologicals [DOI]
- 16 The Merck index: an encyclopedia of chemicals, drugs, and biologicals [DOI]
Cited by 1
Ahmed Shawky Abouzaid, Maissa Yacoub Salem, Eman Saad Elzanfaly · European Journal of Chemistry · 2017
Related research
- Approximate Prediction of Chemical Changes in Peanut Oil during Intermittent Deep Frying Process Using UV-Visible Spectroscopy — shares topic coverage
- Synthesis and Characterization of PVA-Gelatin Hydrogel Membranes for Controlled Delivery of Captopril — shares topic coverage
- Effect of an Angiotensin Converting Enzyme Inhibitor (Captopril) on Liver and Kidney Function Parameters in Plasmodium berghei-Infected Mice — shares topic coverage
- Effect of Captopril on Some Haematological Parameters and DNA Fragmentation in Plasmodium berghei-Infected Mice — shares topic coverage
- Evaluation of Redox Status in Plasmodium berghei-Infected Mice Treated with Captopril — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
1
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.