Femoral Neck Stress Shielding after Birmingham Mid Head Resection Hip Arthroplasty – Case Report and Literature Review
Patrick Weinrauch, Sharon Kermeci
Advances in Research · pp. 1–10 · Published 1 Sep 2015
10.9734/AIR/2015/20640Abstract
We describe the presentation of substantial neck thinning due to stress shielding about a well-fixed Birmingham Mid Head Resection femoral implant. Despite significant resorption of proximal peri-articular bone adjacent to the modular femoral head, secondary bone remodeling about the implant stem and proximal femur has occurred and stress shielding has appeared to stabilize, resulting in a satisfactory clinical outcome to date. For total hip arthroplasty utilizing short femoral implants we recommend consideration of alternative design stems to reduce the risk of stress shielding.
References (14)
- 1 The Australian Orthopaedic Association National Joint Replacement Registry [DOI]
- 2 Birmingham hip resurfacing [DOI]
- 3 Results of Birmingham hip resurfacing at 12 to 15 years [DOI]
- 4 Birmingham hip resurfacing arthroplasty [DOI]
- 5 Ten-year clinical, radiological and metal ion analysis of the Birmingham Hip Resurfacing [DOI]
- 6 Hydroxyapatite-Coated Femoral Implant in Metal-on-Metal Resurfacing Hip Arthroplasty: Minimum of Two Years Follow-Up [DOI]
- 7 Birmingham hip resurfacing: Five to eight year results [DOI]
- 8 Is Mid-head Resection a Durable Conservative Option in the Presence of Poor Femoral Bone Quality and Distorted Anatomy? [DOI]
- 9 The Birmingham Mid-Head Resection Arthroplasty - Minimum Two Year Clinical and Radiological Follow-Up: An Independent Single Surgeon Series [DOI]
- 10 Frequent Femoral Neck Osteolysis With Birmingham Mid-head Resection Resurfacing Arthroplasty in Young Patients [DOI]
- 11 A clinicoradiologic study of the Birmingham Mid-Head Resection device.
- 12 Radiographic changes of the femoral neck after total hip resurfacing [DOI]
- 13 Early results of the Birmingham mid-head resection arthroplasty.
- 14 Femoral neck resorption following hybrid metal-on-metal hip resurfacing arthroplasty: a radiological and biomechanical analysis [DOI]
Cited by 1
R. O'Leary, Melissa D. Gaillard, T. Gross · Journal of Arthroplasty · 2017
Related research
- Musculoskeletal Complications of Sickle Cell Anaemia and Their Management Approaches in Makurdi, Nigeria — shares topic coverage
- The Role of Sensor Based Insole as a Rehabilitation Tool in Improving Walking among the Patients with Lower Limb Arthroplasty: A Protocol for Systematic Review — shares topic coverage
- Evaluation of Functional Outcome and Complications in Wrist Surgery by Total Wrist Arthroplasty and Arthrodesis — shares topic coverage
- Wrist Arthrodesis in Severe Wrist Arthritis in Rheumatoid Arthritis Patients: A Retrospective Study — shares topic coverage
- Cemented Bipolar Hemiarthroplasty for Fracture — shares topic coverage
Article metrics
Real usage data collected on this platform.
56
Page views
0
PDF downloads
14
Outbound clicks
1
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.