We describe the presentation of substantial neck thinning due to stress shielding about a well-fixed Birmingham Mid Head Resection femoral implant. Despite significant resorption of proximal peri-articular bone adjacent to the modular femoral head, secondary bone remodeling about the implant stem and proximal femur has occurred and stress shielding has appeared to stabilize, resulting in a satisfactory clinical outcome to date. For total hip arthroplasty utilizing short femoral implants we recommend consideration of alternative design stems to reduce the risk of stress shielding.  

Hip mid-head resection arthroplasty metal on metal stress shielding

References (14)

  1. 1 The Australian Orthopaedic Association National Joint Replacement Registry [DOI]
  2. 2 Birmingham hip resurfacing [DOI]
  3. 3 Results of Birmingham hip resurfacing at 12 to 15 years [DOI]
  4. 4 Birmingham hip resurfacing arthroplasty [DOI]
  5. 5 Ten-year clinical, radiological and metal ion analysis of the Birmingham Hip Resurfacing [DOI]
  6. 6 Hydroxyapatite-Coated Femoral Implant in Metal-on-Metal Resurfacing Hip Arthroplasty: Minimum of Two Years Follow-Up [DOI]
  7. 7 Birmingham hip resurfacing: Five to eight year results [DOI]
  8. 8 Is Mid-head Resection a Durable Conservative Option in the Presence of Poor Femoral Bone Quality and Distorted Anatomy? [DOI]
  9. 9 The Birmingham Mid-Head Resection Arthroplasty - Minimum Two Year Clinical and Radiological Follow-Up: An Independent Single Surgeon Series [DOI]
  10. 10 Frequent Femoral Neck Osteolysis With Birmingham Mid-head Resection Resurfacing Arthroplasty in Young Patients [DOI]
  11. 11 A clinicoradiologic study of the Birmingham Mid-Head Resection device.
  12. 12 Radiographic changes of the femoral neck after total hip resurfacing [DOI]
  13. 13 Early results of the Birmingham mid-head resection arthroplasty.
  14. 14 Femoral neck resorption following hybrid metal-on-metal hip resurfacing arthroplasty: a radiological and biomechanical analysis [DOI]

Cited by 1

Comparison of Cemented and Bone Ingrowth Fixation Methods in Hip Resurfacing for Osteonecrosis.

R. O'Leary, Melissa D. Gaillard, T. Gross · Journal of Arthroplasty · 2017

Article metrics

Real usage data collected on this platform.

56

Page views

0

PDF downloads

14

Outbound clicks

1

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.