Experimental Evaluation of Optimization in Cr and Dr Digital Radiography Systems: A Study with Anthropomorphic Phantom
Gomes S. T., Schwarz, S. C., Claus V. T.
Current Journal of Applied Science and Technology · pp. 63–76 · Published 5 Sep 2023
10.9734/cjast/2023/v42i284200Abstract
Place and Duration of Study: Sample: The experimental optimization study was conducted at a radiology clinic in Santa Maria, RS, Brazil between June 2022 and December 2022. In this study, we verified the efficiency of two digital radiography image acquisition systems (CR and DR) for a radiographic system. Methodology: We used an anthropomorphic phantom that represents the anatomy of the pelvis region of an adult patient. For image acquisition and dosimetric measurements, the radiographic system and two clinical use image digitization systems were used, and the dosimetric measurements were obtained through a radiation detector. For optimization of the exam, five different exposure techniques were used. With ImageJ software it was possible to obtain the signal and noise values for image quality (IQ) from regions of interest (ROI) defined in the image anatomy. The signal-to-noise ratio (SNR) was calculated. The percentage deviation (D%) was chosen to compare the readings against the reference technique, which is used by radiology professionals in the clinic for pelvic examination. Results: The results obtained in this study point out that the DR system offers a constant SNR and a better visualization of tissues at low contrast when compared to the CR system. It was found that by raising the X-ray tube voltage and reducing the current product by time (70 kV and 32 mAs) to (100 kV and 5 mAs) one can optimize the pelvis radiographic examination for DR system, i.e., the KERMA in the incident air (KAR) was reduced from 2.9 mGy to 0.5 mGy (-76.3%) at the patient's pelvis surface. Average dose reduction in organs from 3.07 to 0.94 mGy (-69.5%) in the testes, 0.69 to 0.33 mGy (-52.2%) in the ovaries, 1.20 to 0.51 mGy (-57.3%) in the prostate, 0.14 to 0.07% (-46.4%) mGy in the bone marrow and 35.3% and 62.2% reduction (0.45 to 0.17) mSv the total effective dose of the exam with IQ higher by 11%.
Cited by 0
No indexed citations yet.
Related research
- Evaluation of the Influence on the Use of Additional Filtration in Pelvic Radiographic Examinations Using a Phantom Object — shares topic coverage
- Quality and Image Processing Analysis versus Radiation Dose in Hip Radiographic Examinations — shares topic coverage
- The Critical Decision: Comparing Chest Radiographs at the Bedside and in the Examination Room — shares topic coverage
- The Influence of Anti-scatter Grid Usage for Knee Computerized Radiography — shares topic coverage
- Computed Radiographic Evaluation of Angle of Gastric Axis to Angle of Liver Tip Ratio (AGA/ACV) in Clinically Healthy Dogs — shares topic coverage
Article metrics
Real usage data collected on this platform.
27
Page views
0
PDF downloads
3
Outbound clicks
0
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.